standard cable is available. A user made cable must be 
connected between the connector pins 9 and 10 where pin 
9 is the CVBS connection and pin 10 the ground 
connection. A 75 ohm coax cable is preferred. 
 
                
 
  
        Figure 2-5: DB15 VGA female connector 
VGA/CVBS connections
PIN
FUNCTION
Monitor ID #2
RED analog video
GREEN analog video
GREEN ground
BLUE analog video
BLUE ground
CVBS analog video
Digital ground
9
8
7
6
5
4
3
2
1
RED ground
SYNC/CVBS ground
Horizontal sync
Vertical sync
Not connected
Monitor ID #0
15
14
13
12
11
10
Monitor ID #1
 
Figure 2-6: VGA connector pinning  
Note 1: The RED, GREEN and BLUE signals are 0.7 Vpp 
signals terminated with 75 ohm load. All other signals are 
TTL level.
 
Note 2: Some type of video cards use monitor ID #0..#2 to 
determine the type of monitor used. The Inca does not 
support automatic monitor detection
 