Philips 320 Manual Do Utilizador

Página de 24
Page 16 
 
2005-12-12 
 
The format of this file is as follows: 
[HOST] 
Domain = yyyy 
 
[DEVICES] 
RAP_DEVICE_1 =  RAP_INCA_320   130.144.84.1 
RAP_DEVICE_4 =  RAP_INCA_320   130.144.84.3 
 
[AUTHORIZATION] 
RAP_DEVICE_ALL = xxxxxxxx 
RAP_DEVICE_4   = yyyyyyyy 
RAP_DEVICE_5   = zzzzzzzz 
 
Note that all entries are case sensitive. 
4.4.1 Host 
The host needs to be configured to be in the same domain 
as the camera, because the host will only detect the 
cameras that are in the same domain as the host is in. The 
name of the domain consists of a set of alphanumerical 
characters without spaces. The default domain is empty 
which results in the default domain. When a domain is 
specified the host will only detect the cameras that have 
the same domain, it won’t even detect the camera’s in the 
empty domain anymore. 
Note that this domain has no relation to the term domain 
as it is used in Windows and is strictly used as a way to 
separate groups of camera’s from each other. 
4.4.2 Devices 
Sometimes a camera can not be automatically detected by 
a host PC, like when the camera is outside of the LAN or 
when broadcasting is disabled. In those cases, the 
detection of a camera can be forced by specifying the 
device ID, the camera type and its IP address. In the given 
example there are two camera’s configured. One with the 
device ID 1 and one with the device ID 4. These device IDs 
need to correspond with the actual device IDs of the 
cameras. 
Then for each device a camera type is specified, which 
should be RAP_INCA_320 followed by the IP address of 
that camera. 
When all cameras are in the LAN and broadcasting is 
enabled, then there is normally no requirement to specify 
them manually. If an IP address is configured for a camera 
in the RapEthernet.ini file and the camera does not have 
that IP address, it is not possible to establish a connection 
with that camera. 
4.4.3 Authorization 
The camera can be protected with a password. In that 
case, when a connection is made with a camera from an 
application on the host, an authorization error is generated 
if the software does not issue the correct password.  
When applications such as “Clicks” or the “Display 
program” are used a popup screen will be displayed, 
making it possible to enter the password. User created 
applications will have to be made in such a way that they 
handle the error correctly.