Pelco CCC1380UH-6X Manual Do Utilizador

Página de 6
 
C2935M-QS (2/06)
6
 
6.
 
Varifocal lens only:
 
 
a.
Set the varifocal to wide (W) and the lens focal length to far (
 
 
).
b.
Adjust the back focus:
(1)
Use a 1.5-mm Allen wrench to loosen the back focus locking screw.
(2)
Turn the lens until the image is focused.
(3)
Tighten the back focus locking screw clockwise.
Back focus is a coarse adjustment. You will make the fine focus adjustment in steps 
c and d.
c.
Move the varifocal locking screw up or down to set the field of view.
d.
Adjust the lens focus to achieve the best fine focus.
e.
Repeat steps c and d until the focus is correct.
7.
 
Manual iris only:
 
 Adjust the iris for the best picture quality. The largest aperture gives 
the best light sensitivity; the smallest aperture gives the greatest depth of field.
8. Tighten all lens locking screws.
9.
 
Auto iris only:
 
 Remove the ND filter.
10. If necessary, reset the AGC setting to its previous value.
a.
Display the FUNCTION SETTINGS menu.
b.
Change AGC to OFF, LOW, or HIGH.
c.
Select EXIT to save the AGC setting.
11.
 
Auto iris only:
 
 Perform the auto iris lens adjustment procedure (refer to 
 
DC Iris Level 
Adjustment
 
).
 
WARNING:  
 
Do not over-tighten the back focus locking screw because you may 
damage the camera. 
 
WARNING:  
 
When tightening the lens locking screws, do not over-turn or force 
any screw.
Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA •  www.pelco.com
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120
REVISION HISTORY
Manual # 
Date 
Comments
C2935M-QS 2/06 Original 
version.
Pelco and the Pelco logo are registered trademarks of Pelco. 
©Copyright 2006, Pelco. All rights reserved.
 
C2935M-QS web.fm  Page 6  Friday, February 10, 2006  11:09 AM