Bosch PT-400 Manual Do Utilizador

Página de 86
Security Escort | Technical Reference Manual | 3.0  System Menus 
and Screens 
EN | 39 
 
 
Bosch Security Systems | 6/12 | 38947D 
 
Point Troubles 
Outputs all reported receiver and alert 
unit troubles. This item is checked for 
devices used to monitor problems. 
Login Changes 
Reports all new system operator login 
and logout activity. 
Network Communications 
Records all communications between 
networked computers. This selection is 
only used for engineering diagnostics. 
Leaving this item selected generates a 
significant amount of history and fills 
up the hard disk drive very quickly and 
may bog down the system during high 
traffic times. Always leave this item 
unchecked. 
Modem Communications 
Records all communications to the modem 
for remote communications and pager 
access. This selection is only used for 
diagnosing pager communication 
problems. Leave this item unchecked. 
Analyze Alarms 
This option outputs data allowing an 
engineer to evaluate how well the 
location algorithm is performing. Leave 
this item unchecked. 
Master Computer Switch 
Records when the master and slave 
computers switch roles. 
Transponder Data View 
Allows the data created by the 
Transponder Data View Screen to be 
output. This selection is only used for 
engineering diagnostics. Leave this 
item unchecked. 
Printer Output 
Allows the data being sent to the 
printer to be sent to other outputs. 
This item is unchecked. 
3.3.3 Popup Trouble Filter 
The Security Escort System contains 
many built-in self testing features. 
Each transponder tests the condition of 
the receivers and alert units connected 
to it.  
When the transponder finds a device 
reporting a trouble condition, it 
communicates the problem and the device 
identity to the central console. This 
generates a brief alert tone, displays 
a pop-up message for the operator, and 
sends an optional pager message. The 
message indicates the nature of the 
trouble and instructs the operator on 
the proper course of action. The status 
of the device is recorded in the 
Transponder Current Status (See Section 
3.3.10  Transponder Current Status 
Screen) file under the Setup Menu. The 
event is recorded on the hard disks of 
both the main and backup computers and 
on the printout. 
Figure 40:  Pop-Up Alert Showing 
Receiver not Responding 
 
Selects which trouble categories cause 
pop-up messages to appear on the 
central console or be sent to the 
service pager. The troubles described 
below are always recorded in the 
Transponder Current Status Screen, but 
might or might not produce a pop-up 
display or pager message, depending on 
the selections made.  
 
 
Figure 411: Pop-up Trouble Filter 
Screen