Bosch PT-400 Manual Do Utilizador

Página de 86
Security Escort | Technical Reference Manual | 3.0  System Menus 
and Screens 
EN | 54 
 
 
Bosch Security Systems | 6/12 | 38947D 
 
Maximum Low Battery Messages 
This value is the maximum number of 
transmitters with low batteries yet to 
be displayed. If displayed in yellow, 
more than 50% of the queue was in use. 
Maximum Test Strobe Messages 
This value is the maximum number of 
test strobes in use at one time. If 
displayed in yellow, more than 50% of 
the queue was in use. 
Max Man Down Messages 
This value is the maximum number of 
transmitters timing man down events, at 
one time. If displayed in yellow, more 
than 50% of the queue was in use. 
Supervision Monitors 
This value is the current number of 
transmitters being monitored for 
supervision transmissions. 
Max Spooler Bytes 
This value is the maximum number of 
bytes spooled for the printer at one 
time. If displayed in yellow, more than 
50% of the queue was in use. 
Max Report Spooler Bytes 
This value is the maximum number of 
bytes spooled for the printer for Guard 
Tour Reports at one time. If displayed 
in yellow, more than 50% of the queue 
was in use. 
Max Receiver Buffer 
This value is the maximum number of 
bytes received from transponders on 
this serial port, but not yet processed 
by the system. If displayed in yellow, 
more than 50% of the queue was in use. 
Max Transmit Buffer 
This value is the maximum number of 
bytes processed by the system, but not 
yet transmitted to the transponders on 
this serial port. If displayed in 
yellow, more than 50% of the queue was 
in use. 
Hardware Overrun 
This is the number of times a byte was 
lost by the hardware for a serial port 
because it was not fast enough to 
process the byte into the input buffer. 
Buffer Overflow Count 
This is the number of times a byte was 
lost by the software for a serial port 
because the input buffer overflowed. 
Bytes were placed into the input buffer 
faster than the system could process 
them. 
Overload Level 
This is a measure of the amount of time 
peak traffic on this serial port was 
greater than the system’s ability to 
handle it. The system automatically 
sheds non-essential tasks when this 
value rises. 
Overload Count 
This is a measure of the number of 
times peak traffic on this serial port 
was greater than the system’s ability 
to handle it. The system automatically 
sheds non-essential tasks when this 
value rises. 
Reset Status 
Pressing this button resets all values 
in this shown in this screen. 
Refresh Data 
Pressing this button refreshes all 
values shown in this screen. The values 
are not automatically updated when the 
screen is left open. 
3.3.17 System Preferences Screen 
The Set System Preferences Screen under 
the Setup Menu contains a number of 
settings that govern the behavior of 
the Security Escort System.
 
Figure 52:  System Preferences Screen 
 
Force Map Background Erase 
Use this checkbox to erase the map 
screen. It should only be checked if 
there are problems with icons not being 
cleared properly from the screen; 
otherwise, it causes the screen to 
flicker.