Viewsonic CDE8451 Manual Do Utilizador
68
If the Command is Not valid, Command Type=”-“
Name Length
ID
Command
Type
CR
Byte
Count
1 Byte 2 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5
Example1: Get Brightness from TV-05 and this command is valid. The
Brightness value is 67.
Send (Hex Format)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x35
0x67
0x62
0x30
0x30
0x30 0x0D
Reply (Hex Format)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x35
0x72
0x62
0x30
0x36
0x37 0x0D
Example2: Get Brightness from TV-05, but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x35
0x67
0XD3
0x30
0x30
0x30 0x0D
Reply (Hex Format)
Name Length
ID
Command
Type
CR
Hex
0x34
0x30
0x35
0x2D
0x0D
Get-Function table
Get Function Length ID Command
Type
Command
Response Range
Comments
(ASCII)
Code (ASCII) Code (Hex) (Three ASCII bytes)
Get-Contrast
8
g
a
61
000 ~ 100
Get-
Brightness
8
g
b
62