8.4 Cutting Component Inspection-Blade Bar
Inspect blade bar assembly for the following: 
OPS-B-0062_A
Inspect the Blades daily for abnormal wear. REPLACE BOTH BLADES on that carrier
IMMEDIATELY if either blade has:
Become bent or deformed from it’s original shape or
Any cracks are visible, or 
Deep gouges in the blade’s surface are present, or
Gouges or chipped areas in the cutting edge are larger than 1/2”(12.7mm), or 
The material on the leading edge has been worn away by more than 1/2(12.7mm)”
Failure to replace abnormally worn blades may lead to catastrophic failure of the blades and ejection of the
broken part with tremendous force which may cause serious bodily injury or death. OPS-U-0032