Problem    
    Possible Cause 
 Remedy 
Spindle Locks Up 
(Seizes and Won't Turn) 
Loss of lubrication in 
spindle 
Indicated by catastrophic failure of the upper 
bearing.  See the previous section 
 
Excessive bearing pre-
load 
Disassemble the spindle and inspect the 
bearings for wear.  Re-assemble following the 
bearing pre-load specifications in the Technical 
Service Manual. 
 
Blade bar bolts too long 
Installing the incorrect bolts (too long) for the 
blade carrier will allow the bolts to contact the 
lower bearing and will lock up the spindle.  
Install the correct bolts. 
 
Interference due to bent 
seal protector 
Inspect the seal guard ring (welded to the blade 
carrier or bar) Replace or repair as needed. 
Starter on Tractor 
Won't Crank 
Wire harness incorrectly 
installed 
Check harness attachment to the ignition switch 
and to the battery.  Also, check for proper 
ground. 
Tractor Battery Dead or 
Low (Continuous 
Power Draining) 
 
 
 
On/Off switch malfunction
Inspect to ensure power to switch is interrupted 
when the switch is in the off position 
 
Short to ground in wire 
harness 
Inspect for damage or heat stress to the 
harness.  Check for shorted wires or melted 
insulation.  Check proper connection to the 
ignition switch and battery. 
 
Battery failure
Test the battery and replace per the tractor 
manufacturers recommendation 
 
Tractor issues 
Follow tractor manufacturer recommendations 
for troubleshooting electrical problems with the 
tractor.