Maintenance Every 1500 Service Hours
Checking or Cleaning the Implement Hydraulics
Suction Filter
-
Remove the mounting pin (4) of the hydraulic cylinder
(5).
-
Remove the banjo screw (3).
-
Remove the filter cover fastening screws (2).
-
Withdraw the filter housing with the sieve-star filter.
ATTENTION
Observe the instructions for handling fuels
and lubricants.
Cleaning:
-
Wash the sieve-star filter with clean Diesel fuel.
Replacement:
-
Unscrew the sieve-star filter from the filter housing
with a 24mm open-ended wrench.
-
Screw the new filter with a new toroidal sealing ring on
to an the filter housing.
The installation of the suction filter is carried out in the reverse
order of removal.
If an implement variable pump* or power hydraulic system*
is installed, an additional sieve-star filter is installed in the
flange (1). If so, it must also be cleaned or changed as