Ariens 920015 COMPACT 26 LE Manual Do Utilizador

Página de 38
GB - 21
CHECK CLUTCH OPERATION
Auger / impeller must stop within 5 seconds 
when attachment clutch/impeller brake lever 
is released.
Wheels must stop quickly when traction drive 
clutch lever is released.
If clutches do not engage or disengage 
properly, adjust or repair before operation 
(see Attachment Clutch/Brake Adjustment on 
page 27 and Traction Drive Clutch 
Adjustment
 on page 29).
CHECK CLUTCH SPRING 
ADJUSTMENT
Make sure the attachment clutch and traction 
drive clutch are adjusted to the range 
specified in Attachment Clutch/Brake 
Adjustment
 on page 27 andTraction Drive 
Clutch Adjustment
 on page 29.
CLEAN ENGINE
Refer to Engine Manual for detailed 
instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked 
every 5 hours of operation. Oil level MUST be 
maintained in safe operating range on 
dipstick at all times or engine damage will 
result (See Engine Manual).
Park unit on a level surface. Refer to Engine 
Manual for detailed instructions.
CHANGE ENGINE OIL
Change oil after first 2 hours of operation, 
thereafter change oil every 25 hours (more 
often if required). Refer to Engine Manual for 
detailed instructions.
Run engine just prior to changing oil. Warm 
oil will flow more freely and carry away more 
contamination. Remove the oil drain plug 
from the rear of the unit and tip the unit back 
to help drain all the oil.
CHECK TIRE PRESSURE
Keep tires at pressure listed on the tire 
sidewall. (see Check Tire Pressure on 
page 11).
CHECK AUGER GEARCASE 
IMPORTANT: 
Proper oil level must be 
maintained.
Gear cases are filled to the correct level at 
the factory. Unless there is evidence of 
leakage, no additional lubricant should be 
required. Check oil level each season or 
every 25 hours of operation.
To ensure adequate lubricant level:
1. Remove filler plug (Figure 17). Lubricant 
must be at least up to bottom of lubricant 
filler hole with unit resting on a level-
surface.
2. Add lubricant if required. Allow oil to 
drain to level of plug and replace plug. 
IMPORTANT: 
Use only Ariens L-3 synthetic 
severe duty gear lube (Part Number 
00068800). 
NOTE: 
Gearcase filler plug may require an 
application of Loc-Tite® 565 thread sealant 
with repeated servicing. If Loc-Tite® 565 is 
not available, use PTFE pipe sealing tape on 
the filler plug.  
Figure 17
1. Auger Gearcase
2. Filler Plug
OS8195