American Standard 2703.XXXW Series Manual Do Utilizador

Página de 4
INSTALLATION INSTRUCTIONS
752352-100 REV. H
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
ELLISSE BUILT-IN™ 
SERIES WHIRLPOOL
2703.XXXW 
2705.XXXW 
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
T H A N K     Y O U . . .
for selecting an American Standard bath. Your new 
bath is shipped to you after careful inspection. The 
whirlpool version is completely assembled with pump, 
motor, and system piping. All you need to finish the 
installation are your selected fittings and electrical 
connections for a whirlpool.
To insure maximum performance and pleasure from 
this product, please follow the instructions and 
cautions. 
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any 
shipping damage. If such damage is found, report it to 
your vendor immediately.
After inspection and during installation, protect the bath 
from construction damage. After installation, and before 
enclosing with wallboard, tile, etc., water test the unit 
and check for leaks.
If a whirlpool, do not make modifications to the whirlpool 
system or remove pump from factory mounting. This 
could adversely affect the safety and performance of the 
whirlpool and void the warranty. Do not handle or move 
the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided 
with the bath and must be ordered separately. Framing 
and enclosing materials are provided by others. Check 
for availability of optional American Standard wall tiling 
bead (required for recess installations).
Protect all finished surfaces of the whirlpool during 
construction and installation using a drop cloth.  
WARNING! Do not lift whirlpool by the piping har-
ness at any time.
List of Optional Components (not included):
•  Apron Kit*
•  Safe-T-Heater 9075.120*
* see your American Standard Distributor
List of Required Components (not included):
•  Drain 1583.470*       •  Bath Filler* 
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun
Supplies
•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  15 or 20 amp GFCI
      Outlet
•  Cement, Plaster,
      Grout
GENERAL SPECIFICATIONS FOR 2703/5 WHIRLPOOL
60 x 32 x 21-1/2 In. (1524 x 813 x 546mm)
141 Lbs. (63 Kg.)
643 Lbs. (292 Kg.)
60 Gal. (277 L)
50 Gal. (189 L)
44-1/2 X 20 In. (1130 mm X 508 mm)
58 X 26-1/4 In. (1473 mm X 667 mm)
14-1/2 In. (368 mm)
 48 Lbs./Sq.Ft. (231 Kgs./Sq.m)
20.8
35.3
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.6 HP, 9.7 AMPS, 120V.
2.1 HP, 15.6 AMPS, 120V.
SYSTEM I PUMP
SYSTEM II PUMP
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
1524mm
(60)
PROVIDE ACCESS
TO PUMP FOR SERVICING
ON ALL INSTALLATIONS
229mm
(9)
387mm
(15-1/4)
51mm
(2)
813mm
(32)
533mm
(21)
1-1/2 N.P.T.
THREADS
1-1/2 O.D.
TAILPIECE
38mm
(1-1/2)
83mm
(3-1/4)
C/L OF DRAIN
       OUTLET
FINISHED 
WALL LINE
C/L OF
SUPPLIES
ON/OFF SWITCH
WATER RETENTION 
FLANGE (3) SIDES
305mm
(12) OPT.
102mm
(4)
95mm
(3-3/4)
546mm
(21-1/2)
ROUGH 
FLOOR
PUMP
ALT. PUMP
LOCATION
19mm
(3/4)
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
WATER 
RETENTION 
FLANGE
UNDERSIDE
OF DECK
FINISHED WALL
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
INTEGRAL 
FEET
C/L OF
OVERFLOW
TOP
OF
DECK
38mm
(1-1/2)
1651-1981mm
(65-78)
OPTIONAL
229x305mm
(9x12) FLOOR
CUTOUT
51mm
(2)
SEE FITTING
SPECS FOR
DIMENSION
SAFE-T-HEATER
REMOVABLE BLANK