Jacuzzi K272000AF 7/06 Manual Do Utilizador

Página de 64
E
N
G
L
IS
H
MOTOR
SERVICE ACCESS 
(WITH INTEGRAL SKIRT)
REMOVABLE SKIRT
ACCESS PANELS
ACCESS AREA
20"
36"
24"
18"
B
A
C
SERVICE ACCESS 
(CORNER BATHS)
A - Preferred access
B - Acceptable alternative if access A is not possible
C - Additional access for equipment (Optional)
RIGHT HAND UNIT SHOWN
NOTE:  Left hand unit access is on the opposite
             side (mirror Image).
(45,7 cm)
(50,8 cm)
(60 cm)
(91,4 cm)
MOTOR
AREA
A
AREA
B
FRONT
In some cases, access may not have been provided because of
the  design  of  the  bath  environment  and  having  full  understanding
that in this case, it may be necessary to remove the unit for service.
If  this  is  the  case,  diagnosing  a  problem  may  not  be  possible
without  complete  access  to  the  plumbing  system.    This  would  ne-
cessitate the removal of the unit.  Although this practice is not com-
monly implemented, it is an acceptable method.
In  some  cases  access  may  have  been  provided  in  Area  A  but
service is required in Area B which requires the unit to be pulled for
service and reinstalled.
If service access has not been provided, it is the homeowner's
responsibility  to  remove  the  bath  and  provide  the  required
access, should a repair become necessary.
Service Access
For partially or fully sunken installations, allow for access to ser-
vice connections.  It is the installer's responsibility to provide suffi-
cient service access.  The recommended minimum dimensions al-
lowable  for  service  to  the  bath  are  shown  in  the  "Service Access"
illustration and on the ROUGH-IN drawing for that tub.
Provide adequate area around unit for air circulation for cooling
the motor and to supply sufficient air to the jets.  Do not insulate this
area or around motor.
Optional RapidHeat
TM
 Service Access
Where  tubs  have  been  ordered  with  the  optional  RapidHeat
TM
heater consider an additional service access.
If service access has not been provided, it is the home owners
responsibility  to  remove  the  bath  and  provide  the  required
access, should a repair become necessary.
Service Access with Skirt
An  optional  skirt  fits  along  the  side  of  the  bath  for  above-floor
installations and is also an access panel for servicing.  Allow a space
of at least 8 inches away from the bath for skirt removal.
The  skirt  is  designed  to  accommodate  the  added  height  of  the
tile, linoleum, or other floor coverings up to 1-1/4" (31,75 mm) above
the floor, and will be flush with the floor when installed.
More detailed instructions on skirt installation are provided with
the optional skirt assembly.
Service Access with Integral Skirt
Service access is through the removable skirt panels.
MOTOR
18"
18"
12"
ALTERNATE
ACCESS
PREFERRED
ACCESS
SERVICE ACCESS 
(WITHOUT SKIRT)
FRONT
(30,5 cm)
12"
(30,5 cm)
(45,7 cm)
(45,7 cm)
18"
12"
SERVICE ACCESS 
(BG55, CAPELLA 60 FRONT LEFT MOTOR CORNER BATH ONLY) 
Preferred access area
(30,5 cm)
(45,7 cm)
20
Jacuzzi Whirlpool Bath   K272000AF  7/06
INSTALLATION INSTRUCTIONS