UNDERMOUNT INSTALLATION INSTRUCTIONS
Installation
A typical installation will have these construction character-
istics.
COUNTER
ALL FOAM FEET MUST BE IN CONTACT WITH LEVEL FLOOR
Unit Protection
If protective film has been removed, reapply film.  For added protection, place a drop cloth or other material in the bottom of bath
for protection.  Be careful not to scratch the bath surface.
Counter Preparation
NOTE:  On pump/motor side of bath, the counter should extend a minimum of 4" 
(10,2 cm) 
past the outer edge of bath, in order
to clear the pump/motor plumbing extending beyond the rim of the bath.
INSIDE EDGE
OF RIM
MOTOR/PUMP
COUNTER
Position the template so that the cutout oval aligns with the
rim edge.
TEMPLATE
BATH RIM
In this position, using a grease pencil, mark on the bath the
center  line  positions  through  the  cut  out  slots.    Remove
template.  Measure from marked center lines to a fixed point
such as a wall.
Transfer these measurements to counter and mark center lines positions.  Position template and cut counter for the desired offset.
STUD WALL
MEASURE FROM
CENTERLINE
MARKS TO WALL 
A
C
D
B
COUNTER
TEMPLATE
D
B
A
C
COUNTER
BATH RIM
COUNTER
BATH RIM
OFFSET
After cutting is complete, perform any needed routing, edge work or polishing to the counter.