 16 
• Keep high pressure hose connected to pump and spray gun while 
system is pressurized.
•  ALWAYS point spray gun in safe direction, and squeeze spray gun 
trigger to release high pressure every time you stop engine. Engage 
trigger lock when not in use.
3.  Remove nozzle from end of nozzle extension.
4.  Use a small paper clip to free any foreign material clogging or 
restricting nozzle (Figure 28).
Figure 28 – Free Foreign Material
5.  Remove lance from spray gun.
6.  Using a garden hose, remove additional debris by back 
flushing water through lance (Figure 29). Back flush between 
30 to 60 seconds.
7.  Reinstall nozzle into lance.
8.  Reconnect lance to spray gun.
Figure 29 – Back Flush Lance
9.  Make sure garden hose is connected to pump water inlet. 
Check that high pressure hose is connected to spray gun and 
pump. Turn on water.
10. Start engine following instructions How to Start Your Power 
Washer.
11. Test power washer by operating with each quick connect 
nozzle.
ENGINE MAINTENANCE
 Unintentional sparking can result in fire or 
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR POWER 
WASHER
• Disconnect the spark plug wire from the spark plug and place the 
wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
ENGINE OIL RECOMMENDATIONS
We recommend the use of high-quality detergent oils acceptable if 
classified for service SF, SG, SH, SJ or higher. DO NOT use special 
additives.
Outdoor temperatures determine the proper oil viscosity for the 
engine. Use the chart to select the best viscosity for the outdoor 
temperature range expected.
S A E   3 0 *
S A E   3 0 *
1 0 W - 3 0 * *
1 0 W - 3 0 * *
5 W - 3 0
5 W - 3 0
* Below 50°F (10°C) the use of SAE 30 will result in hard starting.
**  Above 80°F (27°C) the use of 10W30 may cause increased oil consumption. 
Check oil level more frequently.
NOTE:
Synthetic oil meeting ILSAC GF-2, API certification mark 
and API service symbol with “SJ/CF ENERGY CONSERVING” 
or higher, is an acceptable oil at all temperatures. Use of 
synthetic oil does not alter required oil change intervals.
NOTE:
The engine is equipped with an "Oil Alert System". This 
system will automatically stop the engine before the oil level 
falls below a safe limit. To avoid the inconvenience of an 
unexpected shutdown, always check the engine oil level before 
startup.
Maintenance