Step 4c. Using the provided Allen wrench, loosen the set 
screw several turns to allow installation of the downrod.  
Th read the downrod into the motor coupling until it stops 
turning. Th is will take at least four and a half full turns. 
Step 4d. Tighten the set screw securely with the provided 
Allen wrench to ensure safe operation of your fan.
Step 4e. Slide the motor cover down so that it is fl ush against 
the top of the fan.
Step 4f. Using the three provided screws, attach the motor 
cover to the motor. Tighten securely with the provided 
Phillips screwdriver.
IMPORTANT SAFETY INFORMATION!
Before starting the installation of your ceiling fan, install the threaded 
downrod into the motor coupling and lock the assembly
Prepare for fan installation as follows:
Step 4a.
 Place the motor cover on the downrod as shown.
Step 4b. Route the wires from the motor through the 
Perma•Lock™ downrod and ball assembly.
Tip: Th e downrod has a tapered thread that is designed 
to lock completely when correctly installed. 
CAUTION: Failure to fully lock in the downrod 
before securely tightening the Allen set screw may 
cause the fan to separate from the downrod during 
normal operation!
Perma•Lock™ Downrod 
and Ball Assembly
Motor Coupling
Tapered Thread
Allen Set Screw
FAN PREPARATION
Step 4g. Unsnap one of the switch housing brackets on 
the bottom of the switch housing and set it aside for use 
in step 6c.
Step 4h. To reach the blade holder mounting holes in the 
fan motor, the switch housing cap must be removed. Take 
out the two 8-32
3
/
8
" screws securing the  switch housing cap 
and set them aside for use in step 6c.
Mount Screws
8-32 X 
3
/
8
"
(2)
Switch
Housing
Cap
Switch
Housing
Bracket