Braun 33657 Manual Do Utilizador

Página de 8
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 33675 Rev. A
DOOR             OPENING
90
CENTER IN
DOOR OPENING
CENTER  
 ACROSS
VEHICLE    FRAME
 L
 C
20-1/4"
20-1/4"
40-1/2"
1
All-Thread 
Mounting 
Brackets
Engage Platform Manual 
Release System:  The lift 
cable-activated platform 
manual release is disengaged 
during shipment to prevent 
potential drive chain stretch.  
Handle the lift with care.  En-
gage manual release before 
attempting to install (raise, tilt 
or move) the lift
WARNING
Engage manual 
release before 
attempting to install
(raise, tilt or move) 
lift.  Failure to do so 
may result  in serious 
bodily injury and/or 
property damage.
Figure C
Locate Lift Mounting Brackets 
Locate All-Thread Mounting 
Brackets
1.  Open both doors to 90°.
2.  Locate center of door opening 
(between doors).  Mark the 
center point.
3.  Transfer center point to the 
vehicle frame.  Using a front-
to-rear framing member as a 
guide, transfer the center point 
across chassis to opposite side 
front-to-rear framing member 
(must be 90° to door opening).  
Lift mounting bracket positions 
are based on this center line.
4.  Measure 20-1/4" to left and 
right of the center line to 
achieve the 40-1/2" center-to-
center spacing of all-thread 
mounting studs.  
5.  Clamp the mounting brackets 
securely in place (all-thread 
studs must be vertical). 
 “DOT — Public Use Lift”
 
 NHTSA Vehicle Physical Requirements
Alternative floor structures are allowed 
providing the installed lift system pass-
es all FMVSS 403 requirements.  
Figure A
VEHICLE
CHASSIS MEMBER
16”
Maximum
VEHICLE
CHASSIS MEMBER
All-thread 
Mounting 
Brackets
Mounting Bracket Requirements:
A maximum distance of 16
"
 from the 
outermost mounting bracket to the 
end of the cassette.
All four mounting brackets must be 
connected to the framerails.   
Vehicle Requirements:  
All vehicles with a GVW over 6000 lbs. 
and with unmodified OEM framerails.
Clear Door Opening Width
Maximum Floor-to-Ground 
B
A
C
Figure B
Door Opening Dimensions
Vehicle lift access door opening 
must meet specified dimensions.
Minimum Clear Door 
Opening Height
A
B
C
 
604
 
NA 
  40-1/2"
 
34"
“DOT - Public Use Lift” verifies this platform lift 
meets the “public use lift” requirements of FMVSS 
No. 403.  This lift may be installed on all vehicles 
appropriate for the size and weight of the lift, but 
must be installed on buses, school buses, and 
multi-purpose passenger vehicles other than 
motor homes with a gross vehicle weight rating 
(GVWR) that exceeds 4,536 kg (10,000 lb).
Braun Corporation FMVSS No. 403 
Rev: A
Quick Reference Installation Sheet 33675