Quadra-Fire 839-1440 Manual Do Utilizador

Página de 56
Page 2
Quadra-Fire · Sapphire · 250-7233F
      January 28, 2008
Hearth & Home Technologies welcomes you to our tradition 
of excellence!  In choosing a Quadra-Fire appliance, you 
have our assurance of commitment to quality, durability, 
and performance.
This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation of 
our stoves, inserts and fi replaces.  And yet we are old-fash-
ioned when it comes to craftsmanship.  Each appliance is 
meticulously fabricated and gold and nickel surfaces are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.   From design, to fabrication, to shipping: 
Our guarantee of quality is more than a word, it’s Quadra-
Fire tradition, and we proudly back this tradition with a Lim-
ited Lifetime Warranty.  
We wish you and your family many years of enjoyment in 
the warmth and comfort of your hearth appliance.  Thank 
you for choosing Quadra-Fire.
With warm regards,
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: ON BACK OF APPLIANCE
Manufactured Date
FAN TYPE VENTED CIRCULATOR / VENTILATEUR
CIRCULATOIRE
Blower Electrical Rating / Évaluation du Ventilateur
Électrique:
115 V., 1.5 Amps, 60 Hz, 150 Watts
Thermal E fficiency / E fficacité Thermique
*
84% NG (blower on / avec ventilateur allumé)
82% LP (blower on / avec ventilateur allumé)
* With Maximum horizontal length. / Avec longueur horizontale maximum.
MINIMUM CLEARANCES TO COMBUSTIBLES / ESPACE MINIMUM AUX COMBUSTIBLES
Minimum clearances required from combustible construction for all appliance surfaces. /  Espaces minimum exigés de la construction
combustible aux surfaces de l’appareil.
A.
Side of stove top to side wall
6 in. (152 mm)
Du coté du poêle au coté du mur
B.
Rear of stove top to back wall
3 in. (76 mm)
Le contrôle arrière au mur arrière
C.
Corner of stove top to side wall
1 in. (25 mm)
Du Coin du Poêle au coté du mur
D.
Minimum Alcove Height
54 in. (1372 mm)
Hauteur minimum de l'alcôve
E.
Maximum Alcove Depth
36 in. (914 mm)
Profondeur maximum de l'alcôve
F.
Minimum Alcove Width
36 in. (914 mm)
Largeur minimum de l'alcôve
G.
Mantle Clearance from stove top
23 in. (584 mm)
Espace libre du poéle au manteau
HEA RTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and strong enough to support the stove without a tipping hazard
.
CHEMINÉE:
Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle
sans le hasard de basculer.
C
C
A
A
APPROVED FOR CANADA AND USA TO:
ANSI Z21.88A-2000 / CSA 2.33a-M00 Vented Gas Fireplace Heaters, and
applicable sections of UL307b Gas Burning Heating Appliances for Manufactured
Homes and Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances
for use at High Altitudes.” This appliance is manufactured for operation with
Natural Gas.
For conversion to propane Manufacturer’s Part #844-9730 and instructions must
be used. This appliance may be installed in a bedroom or bedsitting room; in
Canada remote thermostat installation is required.
APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS:
ANSI Z21.88a-2000/ CSA 2.33a-M00 Fournaises au Gaz avec Ventilation,
et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pour
les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas
Fired Appliances for use at High Altitudes”. Cet appareil est manufacturé
pour l’opération avec le Gaz Naturel. Pour une conversion au gaz propane
les pièces du Manufacturier #844-9730 et ses instructions doivent être
utilisées. Cet appareil peut être utilisé dans une chambre à coucherou salle
de séjour; au Canada, l’installation d’un thermostat à distance est exigée.
Date of Manufacture / Date du Manufacturier
2005
2006
2007
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Jan
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETT
E
Made in U.S.A. / Fait Aux États-Unis
250-7241
D
G
WARNING : IMPROPE R INSTALLATION , ADJUSTMEN T, ALTERATION , SERVIC E OR MAINTENANC E CA N CAUS E INJUR Y OR PROPE RTY DAMAGE . REFE R TO THE OWNER’ S INFORMATIO N
MANUAL PROVIDED WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSUL
T A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER
.
AVE RTISSEMEN T: UNE INSTALLATION,
UN AJUSTEMEN T, UNE ALTÉRATION,
UN SERVICE OU UN ENTRETIEN
INCORRECTS
PEUVEN T CAUSER DES DOMMAGES
MATÉRIELS.
RÉFÉREZ-VOUS
AU MANUEL D’INFORMATION
FOURNI AVEC CE T APPAREIL.
POUR ASSISTANCE
OU DES INFORMATIONS
SUPPLÉMENTAIRES
CONSULTEZ
UN INSTALLATEUR
QUALIFIÉ, UNE AGENCE DE SERVICE OU UN FOURNISSEUR DE GAZ.
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESUL T. KEEP CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS
AWAY.
ATTENTION: CHAUD LORQU’I L EST EN OPÉRATION. NE TOUCHE Z PAS. DES BRÛLURE S SÉVÈRES PEUVENT EN RÉSULTER. GARDEZ LES ENFANTS, LES VÊTEMENTS, LES MEUBLES, LA GAZOLINE
ET LES AUTRES LIQUIDES DE VAPEUR INFLAMMABLE ÊLOIGNÉ
S
CAUTION: DO NO T OPERATE THIS APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMEN T OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED
SE RVICE PERSON .
ATTENTION: CE T APPAREIL NE DOI T PAS ÊTRE OPÉRÉ SI LA VITRE ES T BRISÉE, CRAQUÉE OU ENLEVÉE. LE REMPLACEMEN T DU PANNEAU DOI T ÊTRE FAI T PAR UNE PERSONNE
LICENSÉE E T QUALIFIÉE .
P.4.1-02 Canada Minimum pipe (P.4.1-02 Le canada tuyau minimum)
64.08% NG / 65.42% LP
E
A
B
F
A
Top Vent:  Input Rate on “HI” (BTU/Hr)
                  Input Rate on “LO” (BTU/Hr)
                  Maximum Output (BTU/Hr)
                  Main Burner Orifice
Rear Vent: (No vertical) Input Rate on “HI” (BTU/Hr)
                  Input Rate on “LO” (BTU/Hr)
                  Main Burner Orifice
Minimum Inlet Pressure (Inches W.C.)
Maximum Inlet Pressure (Inches W.C.)
Manifold Pressure on “HI” (Inches W.C.)
**Max. Venting, Blower On
For use with Natural Gas
Usage au Gaz Naturel
0-2000’
30,000
21,000
25,000
.1065 (36DMS)
26,000
18,000
.0960 (41DMS)
4.5”
7.0”
3.5”
For use with Propane
Usage au Gaz Propane
0-2000’
30,000
24,500
24,600
.0635 (52DMS)
26,000
20,000
.0595 (53DMS)
11”
14”
10”
Bouche Supérieure:
Puissance Évaluée à “HI” (BTU/Hr)
Puissance Évaluée à “LO” (BTU/Hr)
Puissance Maximum (BTU/Hr)**
Orifice du Brûleur Principal
Conduit postérieur:
Puissance Évaluée (non vertical) à “HI” (BTU/Hr)
Puissance Évaluée à “LO” (BTU/Hr)
    Orifice du Brûleur Principal
Pression Minimum de la Valve (pouces W.C.)
Pression Maximum de la Valve (pouces W.C.)
Pression du Collecteur d’ Échappement à “HI” (pouces W.C.)
** Ventilation Maximum, Ventilateur Allumé
Report No. / Rapport Numéro
061-S-19b-5
MODEL / MODÈLE: SAPPHIRE
  SERIAL  NO.
1445 North HIghway
Colville, WA  99114
www.quadrafire.co
m
007
VENTED GAS FIREPLACE HEATER
FOURNAISE AU GAZ AVEC VENTILATION
NOT FOR USE WITH SOLID FUEL
/
NE PAS UTILISER AVEC LE COMBUSTIBLE
SOLIDE
Serial Number
Model Name
Test Lab & Report No.
t
Senior
___________________________
Alan Trusler
Vice President
Dealer Channel
___________________________
Dan Henry
Vice President
Advanced Technolgies
_________________________
Jason Olmstead
Vice President &
General Manager
___________________________
Steve Tate
Quadra-Fire
Brand Manager
Barcode