Roland FC-300 Manual Do Utilizador

Página de 72
 
66
 
MIDI Implementation
 
Controller Status (Individual area)
 
• Receives Data Set (DT1) in all mode.
• Changes status of AMP CONTROL jack when Data Set (DT1) is 
received.
• Outputs when Data Request (RQ1) is received.
 
Message Display Status (Individual area)
 
• Receives Data Set (DT1) in all mode.
• Outputs when Data Request (RQ1) is received.
 
Message Display User Font (Individual 
area)
 
• Receives Data Set (DT1) in all mode, changes the user font of the 
LCD only in the System Exclusive Mode.
• Data Request (RQ1) is ignored.
*1 The bitmap data of the user font following displayed in LCD.
 
Tuner Display Status (Individual area)
 
• Receives Data Set (DT1) in all mode, changes the display of the 
LCD when only Function Mode Status is TUNER.
• Data Request (RQ1) is ignored.
 
Tuner Pitch Status (Individual area)
 
• Receives Data Set (DT1) when only Function Mode Status is 
TUNER.
• Changes the display of the LCD when Data Set (DT1) is 
received.
• Data Request (RQ1) is ignored.
 
Address (H)
 
Size (H)
Data (H)
Parameter
Description
 
50 00
00 01
00/7F
AMP CON-
TROL 1 Status
OFF/ON
50 01
00 01
00/7F
AMP CON-
TROL 2 Status
OFF/ON
 
Address (H)
 
Size (H)
 
Data (H)
 
Parameter
Description
 
60 00
 00 10
00-07,
20-7D
Line 0
Column 0 data
00-07: User Font
20-7D: ASCII 
characters
:
:
:
60 0F
00-07,
20-7D
Line 0
Column 15 
data
64 00
 00 10
00-07,
20-7D
Line 1
Column 0 data
:
:
:
64 0F
00-07,
20-7D
Line 1
Column 15 
data
 
Address (H)
 
Size (H)
 
Data (H)
 
Parameter
Description
 
68 00
 00 08
00-1F
User Font 1
Line 0 data
*1
:
:
:
68 07
00-1F
User Font 1
Line 7 data
68 08
 00 08
00-1F
User Font 2
Line 0 data
:
:
:
:
68 38
 00 08
00-1F
User Font 8
Line 7 data
 
Parameter
Data
 
User Font line0 data
000xxxxx
User Font line1 data
000xxxxx
User Font line2 data
000xxxxx
User Font line3 data
000xxxxx
User Font line4 data
000xxxxx
User Font line5 data
000xxxxx
User Font line6 data
000xxxxx
User Font line7 data
000xxxxx
 
Address (H)
 
Size (H)
Data (H)
Parameter
Description
 
70 01
00 01
00/7F
C#/D
 
 
 Display 
Status
C#/D
 
 
70 02
00 01
00/7F
D#/E
 
 
 Display 
Status
D#/E
 
 
70 03
00 01
00/7F
F#/G
 
 
 Display 
Status
F#/G
 
 
70 04
00 01
00/7F
G#/A
 
 
 Display 
Status
G#/A
 
 
70 05
00 01
00/7F
A#/B
 
 
 Display 
Status
A#/B
 
 
Address (H)
 
Size (H)
Data (H)
Parameter
Description
 
71 00
00 01
00, 01-06
String 
Number
00: OFF
01: 1-6
71 01
00 01
00, 01-0D
Tuner Note 
Status
00: No Signal
01: C, 02: C#
03: D, 04: D#
05: E, 06: F
07: F#, 08: G
09: G#, 0A: A
0B: A#, 0C: B
71 02
00 01
00, 
01–40–7F
Tuner Cent 
Status
00: No Signal
01: -50
40: 0
7F: 50
FC-300_e1.book 66 ページ 2007年4月24日 火曜日 午前10時10分