Yamaha PM5D-RH V2 Manual Do Utilizador

Página de 409
PM5D/PM5D-RH V2 / DSP5D Owner’s Manual    
Operating section
31
4
Connections and setup
This chapter describes examples of expanded systems using the DSP5D, audio input/output con-
nections, and the setup that will be necessary when starting up the PM5D/DSP5D for the first time.
Examples of systems expanded with the DSP5D
• In order to use “cascade connections” for expansion, you must first specify the machine ID (
that will be the target of control from the PM5D’s panel (
• This system expands the number of input channels to 
96 monaural + 8 stereo.
• To make cascade connections, use a D-sub half-pitch 
68-pin cable to connect the CASCADE IN connector to 
the OUT connector of each respective PM5D and 
DSP5D unit.
• The connection between the PM5D located at FoH and 
the DSP5D located on the stage is routed through the 
DCU5D, via Ethernet CAT5 cable and the CASCADE 
IN and OUT connectors.
• By using two DSP5D units, the number of input chan-
nels is expanded to 144 monaural + 12 stereo.
• To make cascade connections between the PM5D and 
DCU5D, use D-sub half-pitch 68-pin cables to con-
nect the CASCADE IN connectors to the OUT 
connectors of each respective unit.
• Connections between the two DSP5D units are made 
using an Ethernet CAT5 cable and a D-sub half-pitch 
68-pin cable, each connected from CASCADE IN to 
OUT of the two units.
Note
If the PM5D and DSP5D are cascade-connected via the 
DCU5D and you’re not synchronizing to an external word 
clock being input to the PM5D, you should set the PM5D as 
the word clock master and the DSP5D as the slave.
4
Connections and setup
Example of simple input expansion 
(PM5D + one DSP5D unit)
FoH
CASCADE
PM5D
OUT
IN
OUT
IN
DSP5D
CASCADE IN
PM5D + remotely connected input 
expansion 
(PM5D + DCU5D + two DSP5D units)
Stage
FoH
DSP5D
DSP5D
DCU5D
POWER
CASCADE
CASCADE
OUT
OUT
OUT
IN
IN
IN
IN
OUT
IN
CASCADE IN
CASCADE IN
Ethernet CAT5
Ethernet
CAT5
OUT
PM5D