Yamaha PM5D-RH V2 Manual Do Utilizador

Página de 409
10
   Scene memory
94
PM5D/PM5D-RH V2 / DSP5D Owner’s Manual    
Operating section
Using the Recall Safe function
“Recall Safe” is a function that excludes only specific parameters/channels from Recall operations. This differs from the Selec-
tive Recall settings (
1
In the DISPLAY ACCESS section, press the 
[SCENE] key several times to access the 
RECALL SAFE screen shown below.
2
Use the buttons in the screen to select the 
parameters/channels that will be excluded 
from Recall operations.
The function of the buttons in the screen and the pro-
cedures are the same as in the SELECTIVE RECALL 
screen (when SAFE PARAMETER mode is selected), 
except for the fact that HA (Head Amp) SAFE ON/
OFF button is added as a parameter in the INPUT 
SAFE PARAMETER area.
The [RCL SAFE] indicator of the channel strip will 
light for input channels, STEREO A/B channels, and 
DCA groups for which Recall Safe is turned on.
Hint
• In the RECALL SAFE screen, clicking the parameter matrix 
grid will display a “ 
” symbol with a “G” character in the 
center. This “G” indicates that the setting is global, and 
applies to all scenes.
• If desired, you can copy and paste Selective Recall settings 
from the currently selected scene into the RECALL SAFE 
screen (
• If you scroll the scroll bar downward, you will see that the 
CH column of the SAFE PARAMETERS area shows not 
only input channels but also input ports. If you set the HA of 
a certain input port to Recall Safe, the HA of the correspond-
ing channel will also be set to Recall Safe. Even if they are 
assigned to multiple channels, the HA Recall Safe settings 
for corresponding input ports/channels will be linked.
• If necessary, you can turn on the HA+CH button in the 
SAFE KEY MODE SELECT area, so that when recall safe is 
turned on/off using the panel [RECALL SAFE] key or the 
RECALL SAFE button in the CH VIEW screen (INPUT 
VIEW function), recall safe will be also be turned on/off for 
the HA patched to the corresponding channel.
• Separately from the conventional Recall Safe functionality, 
the OUTPUT ISOLATION field allows you to specify output 
channels and parameters excluded from recall to be memo-
rized in SETUP memory (which is not subject to memory 
card load operations) (
3
If you want to use the panel to switch Recall 
Safe on/off for a channel, use the [SEL] key to 
select a channel and then press the SELECTED 
CHANNEL section [RECALL SAFE] key to make 
the key LED light.
Recall Safe will be turned on for the corresponding 
channel.
Note
By default, ALL is selected as the parameters that will be 
excluded from recall. This means that if you turn on Recall 
Safe from the panel, the Recall Safe setting will affect all 
parameters of the channel(s) for which it is turned on.
After you have finished making Recall Safe settings and 
you recall a scene, only the selected channels/parame-
ters will be excluded from the Recall operation.
Note
Recall Safe and Selective Recall can be used together. Chan-
nels/parameters excluded from recall operations by either 
Recall Safe or Selective Recall (or both) will not be recalled.
RECALL SAFE
[RECALL SAFE] key