KD 200-54 P Series
ELECTRICAL
 SPECIFICATIONS
Standard Test Conditions (STC) 
     STC = 1000 W/M
irradiance, 25
o
C module temperature, AM 1.5 spectrum*
KD215GX-LPU
KD220GX-LPU
P
mp
215
220
W
V
mp
26.6
26.6
V
I
mp
8.09
8.28
A
V
oc
33.2
33.2
V
I
sc
8.78
8.98
A
P
tolerance
+5/-0
+5/-0
%
Nominal Operating Cell Temperature Conditions (NOCT) 
    NOCT = 800 W/M
irradiance, 20
o
C ambient temperature, AM 1.5 spectrum*
T
NOCT
45
45
o
C
P
max
155
158
W
V
mp
24.0
24.0
V
I
mp
6.47
6.62
A
V
oc
30.4
30.4
V
I
sc
7.11
7.27
A
PTC
194.6
199.2
W
Temperature Coefficients
P
max
-0.46
-0.46
%/
o
C
V
mp
-0.52
-0.52
%/
o
C
I
mp
0.0065
0.0065
%/
o
C
V
oc
-0.36
-0.36
%/
o
C
I
sc
0.060
0.060
%/
o
C
Operating
Temp
-40 to +90
-40 to +90
o
C
System Design
Series Fuse Rating
15 A
Maximum DC System Voltage (UL)                                                                          
600 V 
Hailstone Impact                                                          
1in (25mm) @ 51mph (23m/s)
* Subject to simulator measurement uncertainty of +/- 3%.  
   KYOCERA reserves the right to modify these specifications without notice.
MODULE 
ChARACTERISTICS
Dimensions: 
59.06in/38.98in/1.8in 
length/width/height
 
(1500mm/990mm/46mm)
Weight:  
41.0lbs (18.6kg)
 
PACKAGING 
SPECIFICATIONS
Modules per pallet: 
20
Pallets per 53’ container: 
38
Pallet box dimensions: 
60in/40in/45in 
length/width/height
 
(1515mm/1005mm/1140mm)
Pallet box weight: 
905lbs (410.0kg)
MOUNTING HOLES        DRAINAGE HOLES        GROUND SYMBOL
.35in (9mm)
.35in (9mm)
Expanded View of Grounding Holes
Frame Cross Section Diagrams
Short Side
Long Side
10.96in 278.5mm
1.8in 46mm
.79in
20mm
.41in
10.3mm
1.8in 46mm
.47in
12mm
1.18in
30mm
STABILIZER BAR 
KD 200-54
10.96in 278.5mm
18.56in 471.5mm
59.06in 1500mm
10.96in 278.5mm
18.56in 471.5mm
.49in
12.5mm
38.98in
990mm
1.8in
46mm
4.45in
113mm
3.23in 82mm
43.3in
1100mm
35.4in 900mm
(IP65)
NEC 2008 COMPLIANT
UL 1703 LISTED
WARNING: Read the instruction 