Cellboost 427W Manual Do Utilizador

Página de 86
6-7-06 - Fifth Proof
3-15
Pre-Start Inspection and Operation
Attachment Installation and Removal
Attachment Lock Pins
The mounting plate located at the front of the machine provides for the easy installation and 
safe use of the wide variety of available attachments. This system is very easy to use, but 
requires the proper use of the attachment lock pins. There are two positions for the attachment 
lock pins, the unlocked position and the locked position. 
Once the machine has picked up an attachment, shut off the engine and rotate the attachment 
locks into the “locked” position (Item 1, Figure 3–19). As you rotate the lock pin, it will drop 
downwards, securing the attachment to the machine. If the lock pin does not drop into the 
locked position, start the engine and either raise or lower the attachment slightly until the lock 
pins snap into place.
Figure 3–19 Attachment Locks in Locked Position
Until the attachment lock pins are fully in the locked position, the attachment has not 
been safely secured to the machine. Do not stand near the attachment until it is fully 
secured to the machine. 
To release an attachment, rotate the attachment locks to the “unlocked” position (Item 1, Figure 
3–20). 
The lock pins will automatically rise, releasing the attachment from the machine. If the 
pins do not release the attachment or are very hard to rotate, start the engine and tilt the 
attachment slightly forwards or backwards until the pins can be rotated.
1
1
2022
Pins Locked
CAUTION