Pre-Start Inspection and Operation
Operating Instructions for a Hydraulic Attachment 
1. Move the engine throttle to the full speed setting.
Raise the attachment off the ground and position it for use.
• Make sure that you are standing on the operator's platform. DO NOT step off of 
the platform when the auxiliary attachment's power is engaged. 
• If you release the AUXILIARY hand control/operator presence control, the 
attachment will automatically stop all motion. 
• The Auxiliary Hydraulics will not function properly unless the HIGH/LOW switch 
in set to the HIGH position.
2. Set the HIGH/LOW switch (Item 2, Figure 3–32) to the HIGH position before activating the 
AUXILIARY control lever. If this switch is not set properly, the auxiliary hydraulics and 
travel controls will not function properly.
3. With your right hand, squeeze the AUXILIARY attachment control lever (Item 1, Figure 3–32) 
towards the hand hold to activate the attachment in the FORWARD motion.  
NOTE: 
The lever is spring loaded and when released, will automatically move from the 
FORWARD motion position to NEUTRAL stopping attachment motion.  
Figure 3–32 Auxiliary Attachment Controls 
4. Lower the attachment to begin work.
5. If you want to reverse the operation of the attachment, move the auxiliary control lever 
(Item 1, Figure 3–32) to the REVERSE position. The control lever will remain in the 
REVERSE  position detent until it is moved to the NEUTRAL position.
CAUTION
1
2
2074-1