Raypak R405 Manual Do Utilizador

Página de 4
CALL
OUT
DESCRIPTION
185
265
335
405
B
BURNER TRAY
1-B
Burner Tray w/Burners (Sea Level)*
005213F
005214F
005215F
005216F
Burner Tray w/o Burner (Sea Level)*
005217F
005218F
005219F
005220F
Burner Tray w/Gas Valve Nat Millivolt
005221F
005222F
005223F
005224F
Burner Tray w/Gas Valve Pro Millivolt
005225F
005226F
005227F
005228F
Burner Tray w/Gas Valve Nat IID
005229F
005230F
005231F
005232F
Burner Tray w/Gas Valve Pro IID
005233F
005234F
005235F
005236F
    2-B
Burner Spacer/Hold Down Kit
005237F
005238F
005239F
005240F
    3-B
Burner
301210/13
301210/19
301210/24
301210/29
    4-B
Burner Orifice Nat. #51 (Sea Level)*
350080F/13 350080F/19 350080F/24 350080F/29
Burner Orifice Pro. #57 (Sea Level)*
350083F/13 350083F/19 350083F/24 350083F/29
5-B
Burner Tray w/o Manifold w/o burners
005265F
005266F
005267F
005268F
C
CONTROLS
1-C
AGS 135∞ (Auto Gas Shut-Off) - Red Epoxy
600892B
600892B
600892B
600892B
2-C
High Limit 140∞ - Black Epoxy
600893B
600893B
600893B
600893B
3-C
P. C. BoardControl IID Units
005241F
005241F
005241F
005241F
  6-C
Fuse PC Board IID Units
005384F
005384F
005384F
005384F
4-C
Thermostat Control MV Units Mechanical
003346F
003346F
003346F
003346F
5-C
Temperature Sensor IID Units
005299B
005299B
005299B
005299B
G
GAS VALVE
1-G
Combination Valve - Nat. MV
003898F
003898F
003898F
003898F
Combination Valve - Pro. MV
003899F
003899F
003899F
003899F
Combination Valve - Nat. IID
003900F
003900F
003900F
003900F
Combination Valve - Pro. IID
004306F
004306F
004306F
004306F
H
HEAT EXCHANGER
1-H
Heat Exchange Assy. Cast Iron (Complete)
005244F
005245F
005246F
005247F
Heat Exchange Assy. Brass (Complete)
005248F
005249F
005250F
005251F
    2-H
Inlet/Outlet Header CI
003759F
003759F
003759F
003759F
Inlet/Outlet Header BR
003760F
003760F
003760F
003760F
    3-H
Return Header CI
002450F
002450F
002450F
002450F
Return Header BR
002451F
002451F
002451F
002451F
    4-H
Tube Bundle
005252F
005253F
005254F
005255F
        5-H
Heat Exchanger Tube (1)
005256F
005257F
005258F
005259F
        6-H
Baffle Kit (8)
005260F
005261F
005262F
005263F
        7-H
Bolt Kit
001303F
001303F
001303F
001303F
        8-H
Header Gasket (9)
800014B
800014B
800014B
800014B
   9-H
Unitherm Governor
062234B
062234B
062234B
062234B
     10-H
U.G. Retainer Spring
850254
850254
850254
850254
  11-H
Bypass Valve
062235B
062235B
062235B
062235B
      12-H
Bypass Spring
850252
850253
850253
850253
  13-H
Drain Valve
500719
500719
500719
500719
  14-H
Sensor Well
003765F
003765F
003765F
003765F
  15-H
Well Retaining Clip
300203
300203
300203
300203
16-H
Inlet & Outlet Flange
003766F
003766F
003766F
003766F
  17-H
Flange Gasket 1 1/2" Connections
062236B
062236B
062236B
062236B
Flange Gasket 2" Connections
800080B
800080B
800080B
800080B
18-H
Rear Drain Plug & Cover
005264F
005264F
005264F
005264F
J
CONTROL BOX
1-J
Ignition Control IID Nat.
004817B
004817B
004817B
004817B
Ignition Control IID Pro.
004818B
004818B
004818B
004818B
2-J
Transformer 120/240/24V
006736F
006736F
006736F
006736F
3-J
Rocker Switch (MV Units) 
006872F
006872F
006872F
006872F
4-J
Rocker Switch (IID Units) 
650903
650903
650903
650903
*FOR ALTITUDES ABOVE 2,000 FEET LEVEL, CONSULT THE FACTORY
**WARNING: The Hydraulic conditions or water chemistry that caused the tube bundle to fail have very likely also
damaged the bypass valve and Unitherm Governor.  We recommend you replace the Unitherm Governor and
inspect the bypass assembly.  Failure to do so could cause premature failure of this replacement part.