Model G0758 (Mfd. Since 2/14)
SECTION 6: MAINTENANCE
Metal  chips  left  on  the  machine  that  have  been 
soaked with water-based coolant will invite oxida-
tion  and  a  gummy  residue  build-up  around  the 
moving  parts.  Use  a  brush  and  shop  vacuum  to 
remove  chips  and  debris  from  the  working  sur-
faces  of  the  mill/drill.  Never  blow  off  the  mill/drill 
with compressed air, as this will force metal chips 
deep into the mechanisms and may cause injury 
to yourself or bystanders.
Remove  any  rust  build-up  from  unpainted  cast 
iron  surfaces  of  mill/drill  and  treat  with  a  non-
staining lubricant after cleaning.
Protect  other  unpainted  cast  iron  surfaces  with 
regular  applications  of  products  like  G96
®
  Gun 
Treatment,  SLIPIT
®
,  or  Boeshield
®
  T-9.  (See 
Accessories on Page 27 for more details.)
An  essential  part  of  lubrication  is  cleaning  the 
components before lubricating them.
This step is critical because grime and chips build 
up  on  lubricated  components  over  time,  which 
makes them hard to move.
Clean all exterior components in this section with 
mineral  spirits,  shop  rags,  and  brushes  before 
lubricating.
DISCONNECT  MACHINE  FROM  POWER 
BEFORE PERFORMING LUBRICATION!
Lubrication
For optimum performance from the machine, fol-
low  this  maintenance  schedule  and  refer  to  any 
specific instructions given in this section.
Daily Check:
• 
Loose mounting bolts.
 
Damaged tooling.
 
Clean debris and built up grime off of machine.
 
Worn or damaged wires.
 
Any other unsafe condition.
Every 8 Hours of Operation:
• 
Lubricate table and column ways (
Page 29).
• 
Lubricate quill outside surface (
Page 31).
Every 40 Hours of Operation:
• 
Lubricate table leadscrews (
Page 30). 
Every 90 Hours of Operation:
• 
Headstock gears (
Page 30). 
• 
Lubricate quill rack (
Page 31). 
Every 120 Hours of Operation:
• 
Lubricate column leadscrew (
Page 29). 
Schedule
To reduce risk of shock or 
accidental startup, always 
disconnect machine from 
power before adjustments, 
maintenance, or service.
Cleaning and 
Protecting
Follow reasonable lubrication practices as 
outlined in this manual. Failure to do so 
could lead to premature failure of machine 
and will void warranty.