Agilent Technologies 5741A Manual Do Utilizador

Página de 132
1    Quick Reference 
12 
Series N5700 User’s Guide  
The Rear Panel – At a Glance 
9
5
7
3
8
4
6
1
2
750W
1500W
6V - 60V
80V - 600V
AC INPUT
ON
OFF
+V
-V
NOT ACTIVE
J2 SW1
GPIB
ANALOG PROGRAMMING
+S+LS NC -LC-S
1 2 3 4 5 6 7 8 9
10/100 Ethernet
LINK
TX
J1
!
!
 
 
1 – AC input connector 
Wire clamp connector for 1500W output models.
 
 
IEC connector for 750W output models. 
2 – DC output connector 
Wire clamp connector for 80V to 600V models. 
Bus bars for 6V to 60V models. 
3 – USB connector  
Connector for connecting to a USB interface. See chapter 4 for setup. 
4 – LAN connector  
Connector for connecting to a LAN interface. LINK LED indicates link integrity. 
TX LED indicates LAN activity. See chapter 4 for LAN setup. 
5 – Analog Programming 
      connector 
 
Connector for the analog interface. Includes output voltage and current limit 
programming and monitoring signals, Shut-Off control (electrical signal), 
Enable/Disable control (dry-contact), power supply ok (Power Supply OK) signal 
and operation mode (CV/CC) signal. (See next page for details)  
6 – SW1 setup switch  
Nine-position switch for selecting remote programming and monitoring modes 
for Output Voltage, Current Limit and other control functions. (See next page for 
details)  
7 – Remote Sense connector  Connector for making remote sensing connections for regulating the load 
voltage and compensating for wiring voltage drop. (See next page for details)  
8 – GPIB connector 
Connector for connecting to a GPIB interface. See chapter 4 for setup. 
9 – Ground screw 
M4x8 screws for making chassis ground connections 
 
WARNING 
SHOCK HAZARD The power cord provides a chassis ground through a third 
conductor. Be certain that your power outlet is of the three-conductor type 
with the correct pin connected to earth ground