Klark Teknik DN540 Manual Do Utilizador

Página de 54
Switch section
DN540
Operator Manual
15
Switch section
The switch section has four switches for: 
changing the compressor mode; switching the 
signal level meter from output signal to input 
signal; external sidechain; and channel linking.
11
LED (red)
Not applicable
On/off status indicator for the BYPASS pushbutton.
12
LED meter
LEVEL
Signal level meter.  The meter has +18dB, +12dB, 
+6dB, 0dB, -6dB and -12dB LEDs for displaying the 
output signal level (default).  When the MTR I/P 
pushbutton is on, the meter displays the input signal 
level.
Item
Type
Label
Function
1
LED (green)
Not applicable
On/off status indicator for the MTR I/P pushbutton.
2
Pushbutton
MTR I/P
Switches the LEVEL meter to monitor the output 
signal (off) or the input signal (on).
3
LED (yellow)
Not applicable
On/off status indicator for the LINK pushbutton.
4
Pushbutton
LINK
Links the channel to the adjacent channel on the 
right.  (There is no LINK button on channel 4.)
5
Pushbutton
EXT
When this button is off, the sidechain signals are 
sourced from the incoming compressor  signal, as 
normal.  When this button is on, these signals are 
sourced from elsewhere via the external sidechain 
input connector (rear panel).
6
LED (yellow)
Not applicable
On/off status indicator for the EXT pushbutton.
7
Pushbutton
AUTO
Selects the compressor mode, where manual 
mode = off (default) and auto mode = on.  For more 
information, see “Modes of operation” on page 23.
8
LED (green)
Not applicable
On/off status indicator for the AUTO pushbutton.
Item
Type
Label
Function
1
2
3
7
8
5
6
4