Grizzly G0467 Manual Do Utilizador

Página de 36
Model G0464/G0465/G0467/G0468/G0470 Air Compressors
-
16
-
Monthly
After the first 50 working hours or 30 days, 
perform the following maintenance:
1.  Change  the  oil  in  the  air  compressor 
pump as described in 
Changing Oil on 
Page 19
Quarterly
After every 300 working hours or 3 months, 
perform the following maintenance:
1.  Change  the  oil  in  the  air  compressor 
pump as described in 
Changing Oil on 
Page 19.
2.  Check  for  air  leaks  and  correct  as 
needed.
Figure 11. Pressure safety valve.
2.  Clean  any  dirt  or  dust  from  the  pres-
sure safety valve. 
3.  Pull the metal ring on top of the safety 
valve  to  ensure  the  valve  will  release 
air. The pressure safety valve must be 
replaced  if  it  cannot  be  pulled,  or  if  it 
leaks after releasing pressure.
 
Note:  The  safety  valve  is  preset  to 
release air if the tank exceeds its maxi-
mum  pressure.  DO NOT  try  to  adjust 
the safety valve pressure setting!
Some  water  may  accumulate  in  the  tank 
depending  on  usage  and  humidity.  Drain 
water  from  the  tank  daily  to  increase  the 
lifespan of the compressor and air tools.
To drain the tank:
1.  Leave  the  tank  pressurized  and  open 
the drain valve, shown in 
Figure 10, to 
drain the water out of the tank.
 
 
Note:  Draining  the  air  from  the  tank 
can  be  extremely  loud.  Wear  ear  pro-
tection when draining the tank.
Draining Tank
The  pressure  safety  valve  prevents  dam-
age to the tank by releasing pressure when 
the tank reaches maximum capacity.
To check the pressure safety valve:
1.  Locate the pressure safety valve shown 
in 
Figure 11.
Figure 10. Tank drain valve.
Pressure Safety 
Valve
Releasing  the  safety  valve  can  be 
extremely  loud.  Protect  your  hearing 
with ANSI approved ear protection.
Pressure 
Safety Valve