troubleshooting
symptom
possible Cause
possible solution
motor will not start 
or is slow to start.
1.  switch disabling key removed.
2.  Break or short in wiring, loose connections, 
plug or receptacle is corroded or mis-wired.
3.  power supply switched off/has incorrect 
voltage.
4.  Blown fuse/tripped circuit breaker at main 
panel.
5.  motor connection wired incorrectly.
6.  motor oN/oFF switch at fault.
7.  motor brake not disengaging.
8.  start capacitor has blown.
9.  Centrifugal switch at fault.
10. motor at fault.
1.  re-install switch disabling key.
2.  trace/replace broken or corroded wires, fix loose 
connections, correct wiring.
3.  switch power supply on/verify voltage.
4.  Correct the cause of overload, then reset/replace 
fuse or breaker.
5.  Wire motor correctly (refer to inside junction box 
cover or manual).
6.  replace switch.
7.  test to see if disc spins freely. if it drags, replace 
motor brake and regulator.
8.  test/replace if at fault.
9.  Adjust/replace centrifugal switch.
10. test for shorted windings or bad bearings; repair or 
replace.
machine has 
excessive vibration 
or noise.
1.  Workpiece loose or incorrectly secured.
2.  motor fan rubbing on fan cover.
3.  motor mounting loose.
4.  lock lever is loose.
5.  Cabinet stand not level.
6.  machine incorrectly mounted to cabinet.
7.  motor bearings worn or damaged.
1.  Use correct holding fixture and re-clamp workpiece.
2.  Fix/replace fan cover; replace loose or damaged 
fan.
3.  tighten mounting bolts/nuts; use thread locking 
fluid.
4.  tighten the lock lever.
5.  Adjust feet as needed.
6.  level/shim base; tighten/adjust mounting hardware 
or feet.
7.  replace motor bearings or motor.
motor overheats.
1.  motor brake not releasing.
1.  test to see if sanding disc spins freely. if not, 
replace motor brake and regulator.
machine stalls or 
slows when operat-
ing.
1.  too much pressure when feeding 
workpiece
2.  Workpiece is warped.
3.  Workpiece is incorrect for machine.
4.  motor connection wired incorrectly.
5.  motor overheated.
6.  Centrifugal switch at fault.
7.  motor at fault.
1.   reduce pressure when feeding workpiece.
2.  straighten workpiece or use a different one.
3.  only sand wood and ensure moisture is below 
20%.
4.  review wiring diagram on motor cover; correct wire 
connections.
5.  let cool, clean motor, and reduce workload.
6.  Adjust/replace centrifugal switch if available.
7.  test, repair, or replace motor.
motor takes longer 
than 7 seconds to 
stop sanding disc.
1.  motor brake components at fault.
1.  replace motor brake components. Call tech 
support if you need assistance.
miter bar binds in 
miter slot.
1.  miter slot dirty or gummed up.
1.  Carefully clean miter slot.
Workpiece angle 
incorrect or out of 
square.
1.  pointer or scale not calibrated correctly. 
miter gauge or table not correctly aligned.