THEORY OF OPERATION
E-3
E-3
POWER WAVE 655/R
INPUT VOLTAGE AND
PRECHARGE
The Power Wave 655/R can be connected for a variety
of  three-phase  input  voltages.    Refer  to  Figure  E.2.
The initial input power is applied through a line switch
located on the front of the machine.  Two phases of the
three-phase input power are applied simultaneously to
the Input Board and both auxiliary transformers.
The  various  secondary  voltages  developed  by  trans-
former T1 are applied to the Input Board, the fan motor
(via a control relay) and the Bus Board rectifier.  The
65VDC produced from the Bus Board rectifier is used
by the Bus Board to provide various DC voltages for
the  Power  Board,  the  Feed  Head  Board,  the
Ethernet/Gateway Board and the wire feeder recepta-
cle.
The 115/230VAC developed on the secondary of auxil-
iary transformer T2 is applied to the 115VAC receptacle
and 
to 
the 
water 
cooler 
receptacle.
The 230VAC supply is also used to operate an auxil-
iary  cooling  fan  in  the  upper  section  of  the  machine.
This fan runs whenever the power switch is ON. 
The large fan in the lower section only runs  when the
machine is producing output. It is activated through a
solid  state  relay  that  responds  to  a  signal  from  the
Control Board.
Two of the input lines are connected to the Input Board,
by way of the input line switch SW1. They are then con-
nected to the input rectifier through the precharge relay
on the Input Board.  During the precharge or "soft start"
sequence,  these  two  phases  are  current  limited  by
resistord on the Input Board. 
The AC input voltage is rectified, and the resultant DC
voltage is applied through a harmonic filter to the input
capacitors located on the right and left switch boards.
A  Voltage  to  Frequency  circuit  on  the  Switch  Boards
sends a signal to the Control Board. When the capaci-
tors have charged to an acceptable level, the Control
Board  signals  the  Input  Board  to  energize  the  main
input contactor (CR-1). At this point the Power Wave
655/R is in the "Run Mode" of operation. If the capaci-
tors  become  undervoltaged,  overvoltaged,  or  unbal-
anced, the Control Board will signal the Input Board to
de-energize  the  main  input  contactor,  and  the  Power
Wave 655/R will be disabled.  See Figure E.2.