OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
TROUBLESHOOTING & REPAIR
F-6
F-6
POWER WAVE 655/R
CAUTION
Major physical or electrical damage
is  evident  when  the  sheet  metal
covers are removed.
Contact  your  local  authorized
Lincoln  Electric  Field  Service
Facility for technical assistance.
Contact the Lincoln Electric Service
Department at 1-888-935-3877
The  input  fuses  repeatedly  fail  or
the input circuit breakers keep trip-
ping.
1.  Make certain the fuses or break-
ers are properly sized.
2.  Make  certain  the  reconnect
panel is configured properly for
the applied voltage.
3.  The welding procedure may be
drawing too much input current
or  the  duty  cycle  may  be  too
high.  Reduce the welding cur-
rent  and/or  reduce  the  duty
cycle.
1.  Check  the  reconnect  switches
and associated wiring.  See the
Wiring Diagram.    
2.  Perform the Input Rectifier
3.  Perform  the  Switch  Board
4.  Perform  the  Input  Contactor