GENERAL DESCRIPTION
The Invertec® V450-Pro offers multi-process CV, CC,
and DC welding and is rated 570 amps, 43 volts at a
60% duty cycle. 
DUTY CYCLE
The  V450-Pro  is  rated  at  570  amps,  60%  duty  cycle
(based  on  a  10  minute  cycle).  It  is  also  rated  at  450
amps, 100% duty cycle.
OPERATIONAL FEATURES and CONTROLS:
UPPER CONTROL PANEL
1. ON, OFF- SWITCH
2. AMPS Meter
• Prior  to  STICK  or  TIG  operation  (current  flow),  the
meter  displays  preset  current  value  (either  +/-  2
amps or +/- 3% (e.g. 3 amps on 100), whichever is
greater).
• Prior to CV operation, the meter displays four dash-
es indicating AMPS unable to be preset.
• During  welding,  this  meter  displays  actual  average
amps.
• After  welding,  the  meter  holds  the  actual  current
value for 5 seconds. Output adjustment while in the
"hold" period results in the "prior to operation" char-
acteristics  stated  above.  The  displays  blink  indicat-
ing that the machine is in the "Hold" period.
3. VOLT METER
• Prior  to  CV  operation  (current  flow),  the  meter  dis-
plays desired preset voltage value (+/- .5V).
• Prior to STICK or TIG operation, the meter displays
the Open Circuit Voltage of the Power Source or four
dashes if the output has not been turned on.
• During  welding,  this  meter  displays  actual  average
volts.
• After  welding,  the  meter  holds  the  actual  voltage
value  for  5  seconds.  The  displays  blink  indicating
that the machine is in the "Hold" period.
• Output adjustment while in the "hold" period results
in  the  "prior  to  operation"  characteristics  stated
above.
4. OUTPUT CONTROL
• Output control is conducted via a single turn poten-
tiometer.  
• Adjustment  is  indicated  by  the  meters  as  stated
above.  
• When in TIG modes, this control sets the maximum
welding  current.  Full  depression  of  a  foot  or  hand
Amptrol results in the preset level of current.  
5. WELD TERMINALS-REMOTE / ON
• Two status lights indicate the location of trigger con-
trol as determined by the "WELD TERMINALS" push
button.  
• If trigger control is local "weld terminals on", the ON
display will be lit.  
• If trigger control is remote "weld terminals remotely
controlled", the REMOTE display will be lit.
• The unit will power up in "pre-determined preferred"
trigger modes.
STICK  = ON
CV = REMOTE
TIG = REMOTE if remote output controls are attached
to the machine.
TIG = ON if remote output controls are not attached to
the machine.
For  all  versions,  these  trigger  modes  can  be  over-ridden
(switched) with the WELD TERMINALS push button. When
changed, the unit will power up in the configuration it was in