TROUBLESHOOTING & REPAIR
F-8
F-8
TROUBLESHOOTING GUIDE
Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
FEEDING PROBLEMS
Meter reads low voltage (1-2 VDC),
and output is extremely low or no
output.
Local/Remote Switch must be in
LOCAL position unless Remote
Control device is attached to remote
receptacle.
1.
2.
3.
4.
5.
See Control Board test.
Poor welding, weld settings drift, or
output power is low.
Check welding procedures and weld
cable connections.
Check with machine on local con-
trol.
Check input voltages and input volt-
age reconnect procedures. See
Installation section of this manual.
1.
Check Mode Switch S2 for dam-
age and continuity.
2.
Check for continuity between
Mode Switch S2 and Control
Board. See Wiring Diagram in
Section G.
3.
Check for loose or faulty con-
nections in heavy current-carry-
ing leads (i.e., choke, shunt,
output bridge, and output
studs). See wiring diagram in
Section G.
4.
5.   See Control Board test
Welding “too hot”. Actual weld cur-
rent is considerably higher than dis-
play indicates. 
Check condition of the shunt and
leads to the Control Board.
If shunt and leads check OK, possi-
ble defective Control Board
V300-PRO
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.  Call
1-888-935-3877.