MAINTENANCE
D-2
D-2
SQUARE WAVE TIG 355
WARNING
SAFETY PRECAUTIONS 
•  Only Qualified personnel should
perform this maintenance.
•  Turn the input power OFF at the
disconnect switch or fuse box
before working on this equipment.
•  Do not touch electrically hot parts.
INPUT POWER FACTOR
CAPACITOR DISCHARGE
PROCEDURE
This procedure ensures that the power factor capaci-
tors are discharged, for greater safety when you are
working on the Square Wave TIG 355 with INPUT
POWER REMOVED.
1.   Remove input power to the machine.
2.   With a 5/16" nut driver, remove the sheet metal
screws that hold the right case side in place.
Remove the right case side.
3.   With a volt/ohmmeter, carefully check the voltage
across the input power factor capacitors.  When
input power is removed, the voltage across each
capacitor should be zero.  (Normally, the capaci-
tors discharge through the primary winding in the
main transformer.)
4.   If capacitor voltage is zero, you may begin working
on the Square Wave TIG 355.