Lincoln Electric 81K2A75-H Folheto

Página de 2
Date: 
12/17/2007 
MSDS No.: 
US-CW751 
Trade Name: 
UltraCore 81K2A75-H
 
Sizes: 
All 
 
Supersedes: 
9/24/2007 
M A T E R I A L   S A F E T Y   D A T A   S H E E T 
For Welding Consumables and Related Products 
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988 
SECTION I - IDENTIFICATION
 
Product Type: 
Flux Cored Electrode 
Manufacturer/ 
Supplier:
 
 
The Lincoln Electric Company 
22801 St. Clair Avenue 
Cleveland, OH  44117-1199 
(216)  481-8100 
 
Classification: 
AWS:  E81T1-K2MJ-H4 
SECTION II  -   HAZARDOUS MATERIAL (1) 
I M P O R T A N T ! 
This section covers the materials from which this product is manufactured.  The fumes and gases produced during welding with the normal 
use of this product are covered by Section V; see it for industrial hygiene information. 
CAS Number shown is representative for the ingredients listed.   All ingredients listed may not be present in all sizes. 
(1)  The term “hazardous” in “Hazardous Materials” should be interpreted as a term required and defined in the Hazards Communication 
Standard and does not necessarily imply the existence of any hazard.   All materials are listed on the TSCA inventory. 
  Ingredients: 
CAS No.
Wt.% 
TLV 
mg/m
3
 
PEL 
mg/m
3
 
Titanium 
dioxides 
13463-67-7
10 10 15 
Nickel (metal)***** 
7440-02-0 
< 5 
1.5 
Manganese and/or manganese alloys and compounds (as Mn)***** 
7439-96-5 
< 5 
0.2 
5 (c) 
Iron 
7439-89-6 1 
10*  10* 
Magnesium and/or magnesium alloys and compounds (as Mg) 
7439-95-4 
0.5 
10* 
10* 
Mineral silicates 
1332-58-7 
< 0.5 
5** 
5** 
Fluorides (as F) 
7789-75-5 
< 0.5 
2.5 
2.5 
Silicon and/or silicon alloys and compounds (as Si) 
7440-21-3 
< 0.5 
10* 
10* 
Titanium and/or titanium alloys (as Ti) 
12719-90-3
< 0.5 
10* 
10* 
Boron alloys (as B) 
11108-67-1
< 0.5 
10* 
10* 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Carbon steel tube 
7439-89-6 
85 
10* 10* 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
 
  
 
 
 
 
 
  
 
 
 
 
 
  
 
 
 
 
 
 Supplemental Information:   
 
(*)            Not listed.  Nuisance value maximum is 10 milligrams per cubic meter.  
PEL value for iron oxide is 10 milligrams per cubic meter.  TLV value 
for iron oxide is 5 milligrams per cubic meter.
 
  
(**
    
As respirable dust.
 
(*****)  Subject to the reporting requirements of Sections 311, 312, and 313 of 
the Emergency Planning and Community Right-to-Know Act of 1986 
and of 40CFR 370 and 372.
 
 
   
 
(c) 
Value is for manganese fume. Present PEL is 5 
milligrams per cubic meter (ceiling value).  Values 
proposed by OSHA in 1989 were 1.0 milligrams per 
cubic meter TWA and 3.0 milligrams per cubic meter 
STEL (Short Term Exposure Limit).   
 
   
SECTION III - HAZARD DATA
 
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products.  See Z49.1 referenced in Section VI. 
Product is inert, no special handling or spill procedures required.  Not regulated by DOT. 
Rev  9/07
                                                                                                                         (CONTINUED ON SIDE TWO)