Toshiba B-EV4D SERIES Manual Do Utilizador

Página de 46
2. PRINTER SETUP 
ENGLISH VERSION EO1-33088 
2.8 Media Sensor Calibration, Self Print Test, and Dump Mode Utilities
 
E2-14 
2.8 Media Sensor 
Calibration, Self Print 
Test, and Dump Mode 
Utilities 
 
2.8.1 Media Sensor 
Calibration 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This utility is used to calibrate the sensitivity of the Feed Gap/Black 
Mark Sensor.  
It is necessary to set the media sensors after the media is changed to 
different type.  
 
 
 
 
1.  First, select the sensor to calibrate in the following procedure.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2.
  Turn off the printer, load the media properly, and close the Top Cover.  
Note: Do not place pre-printed area above the media sensor, as doing 
so disables a correct sensor calibration. 
 
3.  To calibrate the Black Mark Sensor, align the sensor position with the 
black marks on the media.  (Refer to Section 2.7.)  
4.  Press the [FEED] Button while turning on the printer.   
  The Indicator Lamp will light up in the following order: 
Green (Flashing)  
→  Red (Flashing)  →  Orange (Flashing)  →     
Orange  
→  RED  →  Green 
5. Release the [FEED] button when the indicator lamp lights up in red.  
The printer automatically feeds the media to perform a sensor 
calibration.  
Note: If you failed to release the [FEED] button at the right timing, 
retry from Step 4. 
6.  To start the Online operation, turn the printer off, then on again.  
 
NOTE
The sensor type used in the last print
job has been selected.   
The factory default is the Feed Gap 
Sensor.  
Open the Top Cover.
The Indicator Lamp repeatedly lights up in 
different colours at approx. 1.5 sec. interval.  
When the lamp lights up in the colour 
representing the target sensor type, press the 
[FEED] Button.  
The Indicator Lamp 
lights up in green
The Indicator Lamp 
lights up in orange. 
The Indicator Lamp 
lights up in red
The Indicator Lamp is unlit. 
(Reflective (Black Mark) 
Sensor is selected.) 
The Indicator Lamp is unlit.  
(Transmissive (Feed Gap) 
Sensor is selected
.) 
The Indicator Lamp is unlit. 
(“No sensor” is selected.) 
[FEED] Button
[FEED] 
Button 
[FEED] Button
About 3 seconds.
About 3 seconds.
About 3 seconds.
Turn on the printer power.
When the Indicator Lamp is unlit, hold down 
the [FEED] Button for 5 sec. or more, and 
release when the lamp lights up in green.