3.17. Leading Identifiers
They are characters added by the decoder to the leading positions of each code which
inform the host system of the type of symbology decoded. For example, they can be used
when several codes with different symbologies appear on a product or document.
inform the host system of the type of symbology decoded. For example, they can be used
when several codes with different symbologies appear on a product or document.
Two types of identifiers can be used:
3.17.1. Identifier with One Character
Symbology
Identifier
Symbology
Identifier
Code 39
A
Telepen
B
Pharmacode S
Code
93
G
Interleaved 2/5
I
Matrix 2/5
Q
UPC/EAN E
IATA
T
Monarch/Codabar F BC
412
U
Code 128
C
3W7
X
EAN 128
J
Reserved # 1
V
Standard 2/5
R
Reserved # 2
W
MSI
M
Reserved # 3
Y
Plessey P
3.17.2. Identifier with Three Characters
The first character is ] (5D hexa), the second one identifies the type of symbology
read, the third one indicates an option in the symbology. Please consult the AIM
standard to obtain the complete list of identifiers.
read, the third one indicates an option in the symbology. Please consult the AIM
standard to obtain the complete list of identifiers.