Use this table as a guideline for configuring the 6-position dip switch on
your PMC.
your PMC.
Terminators - The SCSI bus (cable) must be properly terminated at each
end of the bus. The first and last device on the bus should be the only
devices that are set to terminate the bus.
end of the bus. The first and last device on the bus should be the only
devices that are set to terminate the bus.
Terminator Power - The SCSI terminators require adequate voltage to
properly terminate the SCSI bus. All SCSI host adapters on the bus should
be set to supply terminator power; and where possible, be located at the
end of the bus and serve as bus terminators.The terminator resistors must
be present on the first and last device on the bus only.
properly terminate the SCSI bus. All SCSI host adapters on the bus should
be set to supply terminator power; and where possible, be located at the
end of the bus and serve as bus terminators.The terminator resistors must
be present on the first and last device on the bus only.
For further information on this PMC, visit the
web site at
Table 4-1. PMC Switch Settings
Switch
On Function
Off Function
Default
1
Use INTA
No Use INTA
On
2
Use INTB
No Use INTB
Off
3
Use INTC
No Use INTC
Off
4
Use INTD
No Use INTD
Off
5
TERM Enable
TERM Disable
On
6
Little Endian
Big Endian
On
Configure the Big/Little endian mode to your appropriate application for proper
software operation.
software operation.
Make sure only one INTx line switch is in the ON position.
Enable TERM ENAB is On only if this SCSI controller is physically at the end
of the SCSI bus. If the SCSI controller is in any other position on the bus, TERM
ENAB must be in the OFF mode.
of the SCSI bus. If the SCSI controller is in any other position on the bus, TERM
ENAB must be in the OFF mode.