Epson EPL-6200 Manual Do Utilizador

Página de 204
EPSON EPL-6200/EPL-6200L
Revision A
Troubleshooting
Troubleshooting When There is Error Display
110
3.2.6  Fuser high temperature problem
†
The following condition is handled as a fuser high temperature problem:
„
During temperature control, the thermistor detected temperature was kept 
above 235
°C over the predetermined period of time.
3.2.7  CPU Error
3.2.8  Engine Communication Error
This error is in communication between the main control circuit and the engine control 
circuit.
Table 3-9. Troubleshooting for “Fuser high temperature problem” 
Step
Action and Question
Yes
No
Parts below can be the source of this error (
• Heater lamp (H1) 
• Thermostat (TS1) 
1
Fuser unit
Replace the fuser unit.
♦Has the error been cleared?
Go to Step 2
Go to Step 5
2
Thermistor (TH1)
Replace the thermistor.
♦Has the error been cleared?
Replace the 
thermistor.
Go to Step 3
3
Heater lamp (H1)
Replace the heater lamp.
♦Has the error been cleared?
Replace the 
heater lamp.
Go to Step 4
4
Thermostat (TS1)
Replace the thermostat.
♦Has the error been cleared?
Replace the 
thermostat.
Replace the 
fuser unit.
5
Main Board Assy.
Replace the Main Board Assy.
♦Has the error been cleared?
Replace the 
Main Board 
Assy.
Go to Step 6
6
Power supply unit
Replace the power supply unit.
♦Has the error been cleared?
Replace the 
power supply 
unit.
Go to 
Table 3-10. Troubleshooting for “CPU Error”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
1
Main Board Assy.
1. Replace the Main Board Assy.
♦Does the error still occur?
Go to 
Replace the 
Main Board 
Assy.
C H E C K
P O I N T
A CPU error can occur depending on the printing data structure 
sent from the host/application to the printer. Therefore, perform 
operation checks in different operation environments and with 
different printing data.
Table 3-11. Troubleshooting for “Engine Communication Error”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
1
Main Board Assy.
1. Replace the Main Board Assy.
♦Does the error still occur?
Go to 
Replace the 
Main Board 
Assy.