Yamaha DSP5D Manual Do Utilizador

Página de 409
GEQ function
170
PM5D/PM5D-RH V2 / DSP5D Owner’s Manual    
Reference section
In this screen you can make settings for Waves Y96K plug-
in DSP cards installed in slots 1–4. For details on opera-
tion, refer to the Y96K operating manual.
Please note that Y96K cards will operate as follows.
• Settings will be stored/recalled as scene data, but the 
Undo function is not supported.
• If you power the PM5D off and then on again, the con-
ventional scene data will be in the state of when the 
power was turned off, but the Y96K will be in the state 
that was last stored or recalled.
• If you recall a scene that produces a major change in 
the Y96K’s settings, the Y96K’s settings will change sev-
eral seconds after recall occurs on the PM5D. If you 
want to match this timing, set the appropriate START 
OFFSET in the FADE TIME screen.
• Do not execute scene store or recall operations while 
the screen indicates that the Y96K is waiting to update. 
If you do so, the screen will become inoperable for up 
to 30 seconds.
• The Y96K’s settings will be saved in the PM5D when 
you store the scene. If in the past you had stored a 
scene with a Y96K installed, and you then once again 
store that scene without the Y96K installed, the previ-
ous Y96K settings will remain. If there is a scene for 
which a Y96K has never been installed, and you install 
a Y96K and then recall that scene, nothing will be 
reflected in the Y96K.
• In PREVIEW mode, the PLUG-IN screen will not show 
the state of the Y96K.
Note
The DSP5D does not support the Y96K.
GEQ function
Here you can adjust the boost/cut for a 31-band graphic 
EQ or 8-band parametric EQ, specify the input/output 
patching, and assign a GEQ to faders.
Module select
This selects the GEQ module to operate. To switch 
between modules, place the cursor here and turn the 
[DATA] encoder, or click the   /   buttons at left or 
right.
LINK button
This button links adjacent odd-numbered 
→ even-
numbered graphic EQ modules. When you turn this 
button on, a window will appear, allowing you to select 
whether the parameters will be copied from one mod-
ule to the other, or whether both modules will be 
initialized.
PLUG-IN screen
PLUG-IN
GEQ PARAM (GEQ parameter) screen
GEQ PARAM
GEQ PARAM
1
5
6 7
2
4
3