Vidikron VP-42HD Manual Do Utilizador

Página de 117
79
EXTERNAL CONTROLS
Application
These specifications cover the communications control of the 
plasma monitor by external equipment.
Connections
Connections are made as described below.
     Plasma Monitor 
 
External Equipment
 
 
 
 
e.g. Personal Computer
1) Connector on the plasma monitor side: EXTERNAL 
CONTROL connector.
Type of connector: D-Sub 9-pin male
No. Pin Name
No. Pin Name
1
No Connection
8
CTS (Clear to send)
2
RXD (Receive data)
9
No Connection
3
TXD (Transmit data)
4
DTR (DTE side ready)
5
GND
6
DSR (DCE side ready)
7
RTS (Ready to send)
2) Connector on the external equipment side: Serial port
(RS-232C) connector.
See the specifications of the equipment that is to be connected
for the type of connector and the pin assignment.
3) Wiring
Use a crossed (reverse cable).
Wire the cable so that each pair of data lines cross between the 
two  devices. These  data  line  pairs  are  RXD  (Receive  data)  and 
TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side 
ready), and RTS (Ready to send) and CTS (Clear to send).
If  DTR  (4)  and  DSR  (6)  are  not  available,  these  2  pins  can  be 
ignored. If RTS (7) and CTS (8) are not available, these 2 pins can 
be tied together.
Communication Parameters
(1) Communication system   
Asynchronous
(2) Interface 
 
 
RS-232C
(3) Baud rate 
 
 
9600 bps
(4) Data length 
 
 
8 bits
(5) Parity 
 
 
Odd
(6) Stop bit 
 
 
1 bit
(7) Communication code 
 
Hex
1
5
9
6
2 3 4
7 8