External Control
 About the external control
This monitor has two external control terminals.
  MAKE/TRIGGER terminal (RJ-45): The following external control 
systems are available.
(1)  MAKE (make contact) system:
 
Controls the monitor by short-circuiting the corresponding pin 
terminal to the GND pin terminal, or disconnecting (opening) it.
(2)  TRIGGER (trigger) system: 
 
Controls the monitor by sending the pulse signal instantaneously 
to the corresponding pin terminal.
  ☞ “Using the MAKE/TRIGGER system”on the right
  RS-232C terminal (D-sub 9-pin): Controls the monitor with the 
RS-232C system. (
☞ “Using the serial communication” on page 43)
Set the following items of “Remote Setting” in Set-Up Menu 
according to the external control terminal and control system. (
☞ 
“Parallel Type” on page 38)
Control 
terminal
Control system
The settings of this unit
“Parallel Type” setting
MAKE/
TRIGGER 
terminal
Parallel Type
MAKE 
Make
TRIGGER
Trigger
RS-232C 
terminal
Serial 
communication 
RS-232C
*
1
  For a monitor connected to a personal computer etc, select the 
terminal the equipment is actually connected to.
“MAKE” takes precedence over other controls.
  You can use external control even when “Control Lock” is set to 
“Volume Lock” or “All Lock”. (
☞ page 39)
  When the monitor is off (on standby), external control is not 
available. But certain external controls (starting/terminating 
communication, turning on the monitor) are available through the 
serial communication. (
☞ page 44)
<MAKE/TRIGGER system>
You can control the monitor by a personal computer or dedicated 
controller*
2
.
  “Using the MAKE/TRIGGER system” on the right.
*
2
  The controller is not commercially available. Consult your dealer if 
you need it.
<Serial communication>
  For the details, see page 43.
PC, etc.
 Using the MAKE/TRIGGER system
The MAKE/TRIGGER terminal is configured as follows. You can assign 
a function to each pin terminal in “Remote Setting”. (
☞ “Pin1, Pin2, 
Pin3, Pin4, Pin5” in “Parallel Type” on page 38)
  You cannot change the functions assigned to the pin terminals 
from 6th to 8th.
Pin No.
Pin name
1
Pin1
2
Pin2
3
Pin3
4
Pin4
5
Pin5
This is a female terminal.
6
Tally*
1
7
Enable*
2
8
GND
*
1
  The 6th pin terminal controls turning on or off the tally lamp 
(available to control even when the 7th pin terminal is invalid).
*
2
  The 7th pin terminal makes the external control valid/invalid. Keep 
the 7th pin short-circuited to 8th pin to make the external control 
valid
To assign the functions to the pin terminals
For the operation procedure, see page 31.
1 
Select “Remote Setting” on the Set-Up Menu.
2 
Set “Parallel Type” to “Set.”
3 
Select a pin name (“Pin1” – “Pin5”) for which you want to assign a 
function, then select the function you want to assign.
 
For the selectable functions, see the table on page 43.
Operation of the external control
1 
Set “Parallel Type” of “Remote Setting” to “Make” or “Trigger” in the 
Set-Up Menu.
2 
Keep the 7th pin terminal (Enable) short-circuited to the 8th pin 
terminal (GND) so that the monitor can be controlled by the external 
control.
3 
When the “MAKE” system is selected: Operate each function by short-
circuiting the corresponding pin terminal to the 8th pin terminal 
(GND) or opening it.
 
When the “TRIGGER” system is selected: Operate each function by 
pulse control, that is short-circuiting the corresponding pin terminal 
to the 8th pin terminal (GND) for about 1 second and opening it.
  When changing the input with MAKE system, activate the pin you 
want after deactivating the currently used pin.
  When selecting the “TRIGGER” system, you can operate only one 
function at a time. Operate the functions one by one.