Panasonic BT-4LH310 Manual Do Utilizador

Página de 76
32
Main Menu 
(Continued)
33
Submenu
Setting
Description
SDI4 FORMAT
AUTO
3G 4:2:2 YCbCr 10bit
3G 4:4:4 YCbCr 10bit
3G 4:4:4 RGB 10bit
3G 4:2:2 YCbCr 12bit
3G 4:4:4 YCbCr 12bit
3G 4:4:4 RGB 12bit
3G 4:4:4 XYZ 12bit
Selects the SDI4 input format.
• For each item, refer to [SDI1 FORMAT].
MAIN MENU 
POSITION
LT
RT
RB
LB
Sets the display position of the main menu.
[LT]   Top left of the screen            [RT]   Top right of the screen
[RB]   Bottom right of the screen      [LB]   Bottom left of the screen
STATUS DISPLAY
OFF
3SEC OFF
CONTINUE
Determines how (→page 16) operating status is displayed.
[OFF]             Not displayed.
[3SEC OFF]    Displayed for approximately 3 seconds after a status change. 
*
1
[CONTINUE]   Always displayed
CRCC ERROR
OFF
ON
Displays a CRCC error for SDI.
[OFF]   Not displayed
[ON]    Displayed
PAYLOAD ID ERROR OFF
ON
Displays a payload ID error for SDI.
[OFF]   Not displayed
[ON]    Displayed
SDI REC TALLY
OFF
TYPE1
TYPE2
TYPE3
Lights the red tally when SDI REC information is superimposed.
[OFF]       Not displayed
[TYPE1]    Lights the red tally in accordance with the record/stop signal in the 
LTC information added to the HD SDI.
[TYPE2]    Lights the red tally in accordance with the record/stop signal in the 
SVITC information added to the HD SDI.
[TYPE3]    Checks the information when another company's camera recorder 
is used and lights the red tally accordingly.
<Note>
•  For details on TYPE1 or TYPE2, refer to "Panasonic Camera Recorders and 
Record/Stop Signals (Recording Mark)" (→page 33).
•  When [GPI CONTROL] is [ENABLE] and the tally item is assigned, tally 
control from the GPI takes priority.
INPUT NAME SETUP
Changes the names of the input connectors to be displayed on the status 
display screen and other screens. 
*
2
SETUP LOAD
FACTORY
USER1 
*
3
USER2 
*
3
USER3 
*
3
USER4 
*
3
USER5 
*
3
Loads the saved factory defaults ([FACTORY]) or user data ([USER1] to 
[USER5]). (→page 22)
After user data is loaded, the screen displays the signal selected before the 
user data was loaded.
SETUP SAVE
USER1
USER2
USER3
USER4
USER5
Saves up to 5 sets of user data. (→page 22)
Menu settings, except [SETUP SAVE]/[SETUP LOAD], and adjustment 
values made with the rotary knob <PICTURE> can be saved.
POWER ON SETUP
LAST
FACTORY
USER1
USER2
USER3
USER4
USER5
Selects the settings to use when the power is turned on.
[LAST]                      Starts up using the settings used immediately before 
the power was turned off.
[FACTORY]              Starts up using the factory defaults.
[USER1] to [USER5]   Starts up using USER registered settings.
*
1
 
When PIXEL TO PIXEL, [3SEC OFF] is equivalent to [CONTINUE].
*
2
 
Up to 12 characters can be entered for this monitor. Only alphabetic characters (English), numeric characters and symbols can be 
used.
*
3
 
[USER1] to [USER 5] and [FACTORY] have the same factory defaults.