Ace Hardware 3209996 Folheto

Página de 2
© 2005 
598-1231-00
3. Testing
1.  Remove the existing fixture.
2.  After screwing the sensor into the wall plate, connect the junc-
tion box wires to the light control wires as shown in Figure 1:
• Black sensor wire to the black (HOT) house wire.
• White sensor wire to all white (NEUTRAL) house and lamp 
wires.
• Red (SWITCHED HOT) sensor wire to black lamp wires.
3.  Mount light fixture according to the instructions that came with 
your fixture.
2. Aiming
Figure 2 - Coverage Angles
240°
8 Ft.
100 Ft.
Figure 1 - Wiring Sensor Head
D
UAL
B
RITE
®
Replacement
Sensor Head
Specifications:
Total Lighting Wattage .. Up to 500 Watts Maximum Incandescent
Range .........................up to 70 ft.; up to 100 ft. with Range Boost
Time Delay ........................................................1, 5, or 20 minutes
D
UAL
B
RITE
®
 ....................................Off, 3, 6 hours, Dusk-to-Dawn
CAUTION: This product is to be used with a U.L. listed rain 
tight or wet location suitable outlet box. Depending on the 
installation, additional hardware may be required.
Note:
 Installation of this light control should be done only by 
those with experience in 120 Volt household wiring. Install in 
accordance with local codes. Some local codes may require that 
a licensed electrician install the light control.
Models 3009701 / 3209996
1. Installation
CAUTION: Always turn the circuit breaker off when wir-
ing the fixture.
For motion sensing,
 put the ON-TIME switch on the bottom of 
the sensor in the 1, 5, or 20 minute position. When motion is detected, 
the lights will come on the selected time. Note: The photocell keeps 
the lights from turning on in daylight.
To keep lights on all night,
 flip the light switch off for 1 second 
then back on. To return the sensor to the motion sensing mode, flip 
the light switch off for 1 second then back on. At dawn, the control 
will return to the motion sensing mode and shut off.
For  accent  lighting,
 set the D
UAL
B
RITE
®
 switch to the 3, 6, or 
Dusk-to-Dawn setting. The lights will turn on dim at sundown for 
the set time. When motion is sensed the lights will turn on full bright 
for the set ON-TIME period. The lights will return to dim during the 
set D
UAL
B
RITE
®
 period.
4. Operation
Turn  the  power  back  on  at  the  circuit  breaker.  Turn  the  light 
switch on.
Note:
 When first turned on wait about 1 
1
/
2
 minutes for the circuitry 
to calibrate.
Put the ON-TIME switch on the bottom of the sensor in the TEST 
position. You can now walk in front of the unit and the lights will come 
on for about 5 seconds. The TEST mode works both day and night.
Walk through the coverage area and point the sensor to obtain the 
desired coverage area. Adjust sensitivity as needed. Use RANGE 
BOOST only if required.
The coverage area for the sensor is shown in Figure 2. The sensor 
should be aimed so that the motion to be detected is in front of and 
across the coverage area. The sensor should be aimed looking out 
at a horizontal angle. To reduce false triggering, point the sensor 
away from traffic areas, air conditioners, dryer vents, water pools, 
or anything which may move or change temperature rapidly.
This  light  control  automatically  turns  on  lights  when  motion  is 
detected. On-time is selectable from Off, 1, 5, or 20 minutes. A 
photocell keeps the lights off during the day. Patented D
UAL
B
RITE
®
 
timer provides accent lighting.
CAUTION: Do not mount the sensor above or touching 
the lamps. Keep regular PAR-38 lamps at least 1" (25 mm) 
from the sensor. Halogen lamps should be kept at least 
2" (51 mm) from the sensor. The sensor bottom must be 
facing down for best coverage and to avoid water damage 
and electrical shock.
Note:
 For under-eave installation, rotate the sensor head 180° by 
bending the sensor towards the clamp bracket. Rotate the sensor 
bottom clockwise away from the bracket.
 BLACK Sensor Wire and 
BLACK Junction Box Wire
 
All WHITE Wires
 RED Sensor Wire and 
BLACK Lamp Wires
Optional: Connect additional load across the white and 
red sensor wires. Total lighting load including lamp-
heads on fixture(s) must not exceed 500W (4.2A).
Junction Box
Lamp 
Holders