Maxtor 10K III Manual Do Utilizador

Página de 284
 SCSI Description
5-40
Maxtor Atlas 10K III
Table 5-50   
Generic Log Parameter-Field Descriptions
Note:
The DU, DS, TSD, ETC, TMC and LP fields are collectively re-
ferred to as the Parameter Control Byte. This byte generally has 
a value of 0; however, if the page is non-volatile but the drive is 
not spun up or the GLTSD bit is set in Mode Page 0Ah, then the 
value would be 20h. If the page is volatile, then the value is 60h.
&*2,
"()**+
Parameter Code
A code which uniquely identifies each parameter on a given Log Page. For 
example, the code 8002h on the Seek Performance Summary page reports 
the average seek time while the same code on the Block Replacement Sum-
mary page reports the number of blocks replaced. 
The following pages in this manual contain the lists of applicable parameters 
for each Log page.
DU
Disable Update. This parameter is 1 when updates are not enabled.
DS
Disable Save. This parameter is 1 when parameters are not saved by the 
drive.
TSD
Target Save Disable. This parameter is 0
indicating that the drive provides 
a target-specific way of saving parameters.
ETC
Enable Threshold Comparison. This parameter is always 0. The drive does 
not use thresholds for any of its parameters.
TMC
Threshold Met Comparison. This parameter is always 0. The drive does not 
use thresholds for any of its parameters.
LBIN
List in Binary. This bit only valid if LP = 1. If LP = 1 and LBIN = 0, then 
the List Parameter is a string of ASCII graphic codes (code values 20h 
through 7Eh). If LP = 1 and LBIN = 1, then the parameter is a list of binary 
information.
LP
List Parameter. When 0, indicates that the parameter value for this param-
eter is a numeric 
When LP is a 1, it indicates that the parameter value 
is an alphanumeric ASCII-string 
This parameter is always 0.
Parameter Length
Specifies the length, in bytes, of the parameter’s value.
Parameter Value
Contains the parameter’s current value when the PC field of the LOG SENSE 
command is 01b.