 SCSI Description
5-64
Maxtor Atlas 10K III
'3%3$3 ?+9*+ -)*+(++2#067
This page defines the methods used by the disk drive to control the reporting and 
operations of specific informational exception conditions. This page applies only to 
informational exceptions that report an additional sense code of FAILURE 
PREDICTION THRESHOLD EXCEEDED to the application client.
Informational exception conditions occur as the result of vendor-specific events 
within a disk drive. An informational exception condition may occur asynchronous to 
any commands issued by an application client.
The data format and field descriptions are described in Table 5-80 and Table 5-81 
respectively. The Codes Used by the MRIE Field are described in Table 5-82.
Table 5-80   
Information Exceptions Control Page-(Page 1Ch)
*
5
>
'
%
$
0
PS
Page Code (1Ch)
Page Length (0Ah)
2 Perf
Reserved
EWASC
DExcpt
Test
Rsv’d
LogErr
3 Reserved
MRIE
4 - 7 
(MSB)
Interval Timer
(LSB)
8 – 11 
(MSB)
Report Count
(LSB)