Maxtor 10K III Manual Do Utilizador

Página de 284
 SCSI Description
5-114
Maxtor Atlas 10K III
< <
"%% (* 2 3 29;13
The READ DEFECT DATA (12) command directs the drive to report defect 
information about the drive’s medium. Refer to the FORMAT UNIT command for 
information about defects. The data sent to the host in the command’s data-in buffer 
transfer consists of a four-byte Defect List header (Table 5-144 anTable 5-145), 
followed by any Defect Descriptors (Table 5-142 and Table 5-143). 
The READ DEFECT DATA (12) Command Descriptor Block is shown in Table 5-
140
; the data fields are described in Table 5-141.
Table 5-140   
READ DEFECT DATA (12) Command-Data Format
*
5
>
'
%
$
0
Operation Code (B7h)
Reserved
Plist
Glist
Defect List Format
2 - 5
Reserved
6 - 9
(MSB)
Allocation Length
(LSB)
10
Reserved
11
Control