SCSI Description
Maxtor Atlas 10K III
5-137
Table 5-176   
Supported Sense Keys
(/5
+,
"()**+
NO SENSE
0h
There is no specific sense key information to be reported for the designated 
logical unit. This is the case for a successful command or a command that 
received CHECK CONDITION or COMMAND TERMINATED status because 
one of the following bits is set to 1: File Mark, EOM, or ILI.
RECOV-
ERED ERROR
1h
The last command completed successfully with some recovery action per-
formed by the drive. Details may be contained in the additional sense bytes 
and the Information field. When multiple recovered errors occur during one 
command, the choice of which error to report (first, last, most severe, etc.) 
is device specific.
NOT READY
2h
The logical unit cannot be accessed. Operator intervention may be required 
to correct this condition.
MEDIUM 
ERROR
3h
The command terminated with a non-recovered error condition that was 
probably caused by a flaw in the medium or an error in the recorded data. 
This sense key can also be returned if the drive is unable to distinguish be-
tween a flaw in the medium and a specific hardware failure (Sense Key
HARDWARE 
ERROR
4h
The drive detected a non-recoverable hardware failure while performing the 
command or during a self-test. The error type could be controller failure, de-
vice failure, etc.
ILLEGAL 
REQUEST
5h
The drive detected an illegal parameter in the Command Descriptor Block or 
in the additional parameters supplied as data for some commands. If the 
drive detects an invalid parameter in the Command Descriptor Block, it ter-
minates the program without altering the medium. If the drive detects an 
invalid parameter in the additional parameters supplied as data, the drive 
may have already altered the medium. This sense key may also indicate that 
an invalid IDENTITY message was received.
UNIT 
ATTENTION
6h
The drive generates this sense key whenever the drive is reset by a TARGET 
RESET message, a hard reset condition, or by a power-on reset. Other con-
ditions that generate a UNIT ATTENTION include:
• The mode parameters in effect for this initiator have been changed by an-
other initiator.
• The microcode has been changed.
• Tagged commands queued for this initiator were cleared by another initi-
ator.
• INQUIRY data has been changed.
• The mode parameters in effect for the initiator have been restored from 
non-volatile memory.
• Other events that require the attention of the initiator.
DATA 
PROTECT
7h
A Read or Write command was attempted on a sector that is protected for 
this operation. The requested operation was not performed.
VENDOR 
SPECIFIC
9h
This sense key is used to report specific Maxtor conditions.
ABORTED 
COMMAND
Bh
The drive aborted the command. The initiator may be able to reissue the 
command successfully.
MISCOM-
PARE
Eh
The source data did not match the data read from the medium (i.e., a mis-
match).