3-16  Maxtor Atlas 10K III
<
678&'( '* "(()!"# 8
12$%
68-Pin Wide LVD Pin Assignments
Note:
The conductor number refers to the conductor position when 
using 0.635 mm (0.025 inch) centerline flat ribbon cable. Other 
cable types may be used to implement equivalent contact assign-
ments.
$3'33
#*4*,*0+)+
The cable plug connector that mates with the 68-pin hard disk drive connector is 
the AMP AMPLIMITE .050 Series III, part number 749925-5.
SIGNAL 
NAME
CONNECTOR 
CONTACT 
NUMBER
CABLE CONDUCTOR 
NUMBER
CONNECTOR 
CONTACT 
NUMBER
SIGNAL 
NAME
+DB (12)
1
1
2
35
–DB (12)
+DB (13)
2
3
4
36
–DB (13)
+DB (14)
3
5
6
37
–DB (14)
+DB (15)
4
7
8
38
–DB (15)
+DB (P1)
5
9
10
39
–DB (P1)
+DB (0)
6
11
12
40
–DB (0)
+DB (1)
7
13
14
41
–DB (1)
+DB (2)
8
15
16
42
–DB (2)
+DB (3)
9
17
18
43
–DB (3)
+DB (4)
10
19
20
44
–DB (4)
+DB (5)
11
21
22
45
–DB (5)
+DB (6)
12
23
24
46
–DB (6)
+DB (7)
13
25
26
47
–DB (7)
+DB (P)
14
27
28
48
–DB (P)
GROUND
15
29
30
49
GROUND
DIFFSENS
16
31
32
50
GROUND
TERMPWR
17
33
34
51
TERMPWR
TERMPWR
18
35
36
52
TERMPWR
RESERVED
19
37
38
53
RESERVED
GROUND
20
39
40
54
GROUND
+ATN
21
41
42
55
–ATN
GROUND
22
43
44
56
GROUND
+BSY
23
45
46
57
–BSY
+ACK
24
47
48
58
–ACK
+RST
25
49
50
59
–RST
+MSG
26
51
52
60
–MSG
+SEL
27
53
54
61
–SEL
+C/D
28
55
56
62
–C/D
+REQ
29
57
58
63
–REQ
+I/O
30
59
60
64
–I/O
+DB (8)
31
61
62
65
–DB (8)
+DB (9)
32
63
64
66
–DB (9)
+DB (10)
33
65
66
67
–DB (10)
+DB (11)
34
67
68
68
–DB (11)