Maxtor 10K III Manual Do Utilizador

Página de 284
Specifications
Maxtor Atlas 10K III
4-5
<
The Maxtor Atlas 10K III hard disk drive operates from two supply voltages:
<
"?# @()'(
You may apply the power in any order or manner, or open either the power or 
power return line with no loss of data or damage to the disk drive. However, 
data may be lost in the sector being written at the time of power loss. The drive 
can withstand transient voltages of +10% to –100% from nominal while 
powering up or down.
<
"?# +! '%'!+
When powering up, the drive remains reset (inactive) until both rising Voltage 
thresholds reset limits are exceeded for 100 ms. When powering down, the drive 
resets immediately when either supply voltage drops below the falling voltage 
threshold.
Table 4-4   
Power Reset Limits
1
A! / 3%B$3>B>$3%
+12 V
±10%
+5 V
±5%
Allowable ripple and noise for each voltage:
+12 V
250 mVp-p
+5 V
800 mV p-p (100 Hz to 8 KHz)
250 mV p-p (8 KHz to 20MHz)
"< ! 
"
+5 V
V
Threshold
 = 
4.175V typical 
4.0V minimum
4.35V maximum
+12 V
V
Threshold
 =
9.5V typical 
9.0V minimum
10.0V maximum